Ariterm KMP Uno Installation And Maintenance Manual

Ariterm KMP Uno Installation And Maintenance Manual

Installation and maintenance for boiler

Advertisement

INSTALLATION and
MAINTENANCE
UNO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KMP Uno and is the answer not in the manual?

Questions and answers

Summary of Contents for Ariterm KMP Uno

  • Page 1 INSTALLATION and MAINTENANCE...
  • Page 2: Table Of Contents

    The heating cartridge can also be disconnected by the switch on the panel. ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 2/28...
  • Page 3: Delivery Details

    15. Drainange valve The delivery includes: • Tapwater exchanger of copper pipes • 4-way shunt with clamped connections • 4 pcs. feet with counter nuts • 1 pc. drainage valve • 1 pc. installation and maintenance manual • 2 pcs. hose clamps • 1 m pellet hose • 1 pc. hose adapter • 1 pc. stop plate for burner • 1 pc. angled flue gas pipe with soot door • Integrated heating cartridge 6 or 9 kW* • 3 pcs. transformer (only for 9 kW) * For 9 kW a current limiter with 2 hours delay at power failure is included. ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 3/28...
  • Page 4: Dimensions And Technical Data

    Tap water volume ............3 lit. Weight ............approx. 180 kg Efficiency ............approx. 90% Max. working temperature ......... 95°C Max. working pressure ..........2,5 bar Draught requirement ......15 Pa (0,15 mbar) Return temperature ..........> 55°C ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 4/28...
  • Page 5: Installation

    Pull the bottom edge of the front panel forwards. Bend the panel to allow the edges to pass the hinges. d) The side panels can now be lifted off. ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 5/28...
  • Page 6: Boiler House And Chimney

    Cleaning access Install the boiler min. 100 mm from the wall/chimney for easy service. Also leave room for eventual cleaning access in the chimney. ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 6/28...
  • Page 7: Pipe Connection

    To be used for radiator circuit in the basement or if no shunt valve is used. • Socket for shunt valve (only 6 or 9 kW). The supplied shunt valve is secured with an gasket in between and 2 pcs. M8 nuts. Hot water / expansion Expansion chamber Hot water outlet Cold water inlet ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 7/28...
  • Page 8: Electrical Installation

    After a power failure half of the boiler output is saved in the boiler to avoid stress of the main supply. The barrier can be disconnected by shortcutting the the two terminals marked TF. The delay will then be only 20 seconds. ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 8/28...
  • Page 9 Two M5-screws hold the electic panel towards the compressor bracket. c) Two screws on each side above the front door hinges. d) The electric panel is free to bend down to give access to the terminals. ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 9/28...
  • Page 10: Wiring Diagrams

    PELLET BOILER UNO Wiring diagram 0 kW Gn/Y(3) Gn/Y (4) Blue (5) Gn/Y Blue (30) Blue White White Brown (25) Blue ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 10/28...
  • Page 11 PELLET BOILER UNO Wiring diagram 6 kW Gn/Y(3) Gn/Y (4) Blue (5) Gn/Y Blue (30) Blue White White Brown (25) Blue ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 11/28...
  • Page 12: Wiring Diagrams

    PELLET BOILER UNO Wiring diagram 9 kW Gn/Y(3) Gn/Y (4) Blue (5) Gn/Y Blue (30) Blue White White Brown (25) Blue Red (15) ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 12/28...
  • Page 13: Feeder And Hopper

    If the screw length is too short, it is recommended to arrange an intermediate hopper to which a feeder screw with standard length can be connected. ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 13/28...
  • Page 14: Operation Start

    80 - 85˚C. The electrical thermostat is set 20 - 30˚C lower to make electrial heating start in case of an unintential burner breakdown but not to switch on at normal operation. ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 14/28...
  • Page 15: Burner Settings

    For optimal setting, a flue gas gauge should be used (ask your installation technician). Correct setting of the air quantity is important for economic combustion. Grey or black chimney smoke indicates too little air. White smoke mostly consists of steam, which is normal during certain weather conditions. ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 15/28...
  • Page 16: Accumulator Tank

    The boiler temperature may not exceed 95˚C before the tank has reached the set temperature (80˚C is recommended) and the burner is switched off. ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 16/28...
  • Page 17: Maintenance

    Also check that the turbulators run freely in the tubes by pulling the rocker straight upwards and then drop it down. Put the cover back in the proper position. • Once a year the burner should be cleaned between the inner and outer tubes. • The pellet hopper should be totally emptied and cleaned from shavings once a year. ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 17/28...
  • Page 18: Maintenance

    7. Remount in reverse order. shaft notch. NOTE! In case of iginition failure; do not open the fireplace door until the combus- tion chamber is well ventilated! Fig. 5 Ignition element ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 18/28...
  • Page 19: Troubleshooting And Repair

    Normally heating element will glow 1 minute after finished start dose. If no glow, first check all wires and connections, then the glow coil (120 - 145 Ohms). If alright, change the ignition controller. ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 19/28...
  • Page 20: Exploded View Stoker

    PELLET BOILER UNO Exploded view burner ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 20/28...
  • Page 21: Warranty

    PELLET BOILER UNO Warranty For warranty issues Ariterm Sweden AB refers to our local Distributor. ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 21/28...
  • Page 22: Installation Cetificate

    PELLET BOILER UNO ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 22/28...
  • Page 23 Postal address ................Sold by: Installed by: Name ............ Company ..........Name ............ Company ..........Address ......................... Address ......................... Postal adress ......................Postal adress ......................Telephone ..........Mobile ..........Telephone ..........Mobile ..........ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 23/28...
  • Page 24 PELLET BOILER UNO ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 24/28...
  • Page 25 Postal address ................Sold by: Installed by: Name ............ Company ..........Name ............ Company ..........Address ......................... Address ......................... Postal adress ......................Postal adress ......................Telephone ..........Mobile ..........Telephone ..........Mobile ..........ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 25/28...
  • Page 26 PELLET BOILER UNO ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 26/28...
  • Page 27 PELLET BOILER UNO ARITERM SWEDEN AB Installation Instructions - 2008.05.21 - 27/28...
  • Page 28 If these instructions are not followed during installation, operation and maintenance, the obligations of Ariterm Sweden AB under the warranty regulations are no longer binding. Ariterm reserve the right to alter any details and specifications without prior notice. Ariterm Sweden AB Flottiljvägen 15, SE-392 41 Kalmar...