NO POWER
the voltage to all lines
Check 'Power Failure' Circuit.
Power Failure Line
MAIN IC (IC5500) W7 pin

TROUBLESHOOTING FLOW CHARTS

Is
fuse open?
No
Is
the voltage
to "5V_STBY" line
supplied?
Yes
Is
supplied?
Yes
(or the voltage to some lines is not supplied.)
After a few seconds, the set will be switched off.
Yes
Check: Power Unit
No
Check: Power Unit
All 0V
No:
(except '5V_STBY' line)
Check: arround
MAIN IC (IC5500),
Crystal (X5500), Power Unit
Diod
Detected Voltage
D1641
D1621
D1668
D6702
– 32 –
9V
5V
AUDIO_POW
3.3V