1.6.1.4 Indoor Equipment Operating Limits
Line Voltage
Line Frequency
Line Distortion
Power for indoor
workstation
Humidity
Temperature
Altitude
Static Discharge
Shock
Heat Output
6 SeaSpace Corporation
90-132 VAC or 190-260 VAC, single-phase
47 - 63 Hz
<10% total harmonic distortion
100/110 V: minimum 8 Amps @ 120 VAC, single-phase
Provide a 15-Amp circuit, isolated ground, 110 VAC, single-phase, 2 outlets
220 V: minimum 6 Amps @ 220 VAC, single-phase
Provide a 10-Amp circuit, isolated ground, 220 VAC, single-phase, 2 outlets
30-85% RH, non-condensing
10° C (50° F) to 35° C (95° F)
0 to 3000 m (10,000')
12 KV with no recovered errors
3 g, 3 axis 1/2 sine, 11 ms
2070 BTU/hr (Add 600 BTU/hr for each person using the system.)