Two-Tone Tone Groups - ZETRON 748 Technical Manual

Repeater manager/teleconnect
Table of Contents

Advertisement

Two-Tone Tone Groups

Table 14 should be used to select the two-tone tone groups for Model 748 100-call programming.
Use the Zetron group number, from 1 to 12 as shown.
Zetron
Group
1
Number
Mfr. Tone
Groups
Mot 1
Mot 2
T
0
330.5
569.1
O
1
349.0
600.9
N
2
368.5
634.5
E
3
389.0
669.9
4
410.8
707.3
N
-
U
5
433.7
746.8
M
6
457.9
788.5
B
7
483.5
832.5
E
8
510.5
879.0
R
9
539.0
928.1
Diagonal
569.1
979.9
025-9368H
Table 14. Two-Tone Tone Group Frequencies
2
3
4
Mot 3
Mot 4
Mot 5
1092.4
321.7
553.9
288.5
339.6
584.8
296.5
358.6
617.4
304.7
378.6
651.9
313.0
399.8
688.3
953.7
422.1
726.8
979.9
445.7
767.4
1006.9
470.5
810.2
1034.7
496.8
855.5
1063.2
524.6
903.2
569.1
569.1
979.9
5
6
7
Mot 6
Mot A Mot B Mot Z GE A' GE B' GE C'
1122.5
358.9
371.5
1153.4
398.1
412.1
1185.2
441.6
457.1
1217.8
489.6
507.0
1251.4
543.3
562.3
1285.8
602.6
623.7
1321.2
668.3
691.8
1357.6
741.3
767.4
1395.0
822.2
851.1
1433.4
912.0
944.1
979.9
979.9
979.9
Quick Reference
8
9
10
346.7
682.5
652.5
384.6
592.5
607.5
426.6
757.5
787.5
473.2
802.5
832.5
524.8
847.5
877.5
582.1
892.5
922.5
645.7
937.5
967.5
716.1
547.5
517.5
794.3
727.5
562.5
881.0
637.5
697.5
979.9
742.5
742.5
11
12
667.5
712.5
772.5
817.5
862.5
907.5
952.5
532.5
577.5
622.5
742.5