  • Page 1 Installation and maintenance instructions For the competent person Installation and maintenance instructions vSMART vSMART GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40   D-42859 Remscheid Tel. +49 21 91 18‑0   Fax +49 21 91 18‑28 10 info@vaillant.de   www.vaillant.de...
  • Page 2: Table Of Contents

    Checking the scope of delivery......7 Minimum clearances..........8 Observing the requirements for the installation site ................. 8 Installing the communication unit ......8 Installing the thermostat........10 Carrying out the electrical installation .... 12 Installation and maintenance instructions vSMART 0020212888_01...
  • Page 3: Safety

    Risk of death from electric shock may arise. Warning. The Vaillant vSMART controller controls a Risk of minor personal injury heating installation with a Vaillant boiler with eBUS interface in a way that is weather-con- Caution.
  • Page 4: General Safety Information

    (known as "fixed installation"). ▶ Immediately rectify any faults and damage that may affect safety. Installation and maintenance instructions vSMART 0020212888_01...
  • Page 5: Requirements For Lines

    ▶ The controller should only be installed in ards, guidelines and laws. dry rooms. 1.4.4 Risk of material damage caused by using an unsuitable tool ▶ Use the correct tool to tighten or loosen screw connections. 0020212888_01 vSMART Installation and maintenance instructions...
  • Page 6: Notes On The Documentation

    These instructions apply for the following only: Description Article number vSMART 0020197226 Status LED buttons Small wall socket: Ther- Communication unit mostat Display Wall socket: Communic- Thermostat ation unit Bluetooth button/comfort Product stand protection mode button Large wall socket: Thermostat Installation and maintenance instructions vSMART 0020212888_01...
  • Page 7: Information On The Identification Plate

    Power supply unit for communication unit The CE label shows that the products comply with the basic Batteries for the thermostat requirements of the applicable directives as stated on the Enclosed documentation identification plate. 0020212888_01 vSMART Installation and maintenance instructions...
  • Page 8: Minimum Clearances

    Position the wall socket at a suitable location on the wall and take the cable duct for the eBUS line into consider- ation. Installation and maintenance instructions vSMART 0020212888_01...
  • Page 9 When you route the line from the underside of the wall ◁ socket to the eBUS connector, use the strain relief (3). The LED on the communication unit flashes blue. 0020212888_01 vSMART Installation and maintenance instructions...
  • Page 10: Installing The Thermostat

    Remove the wall socket from the rear of the thermostat. Position the wall socket at a suitable location on the wall. Observe the minimum clearances (→ Page 8). Installation and maintenance instructions vSMART 0020212888_01...
  • Page 11 Check the RF connection between the thermostat If necessary, reduce the distance between the thermo- and communication unit (temperature indicator on the stat and communication unit. display; see operating instructions). 0020212888_01 vSMART Installation and maintenance instructions...
  • Page 12: Carrying Out The Electrical Installation

    Make sure that the bridge is installed between the "24 V switch is turned off. = RT" terminals. ▶ Switch the main switch off before working on the electronics box of the boiler. Installation and maintenance instructions vSMART 0020212888_01...
  • Page 13: Operating Concept

    To prevent malfunctions, inform the operator of the fol- Service. lowing regulations: – The heating installation must only be operated if it is in a perfect technical condition. – Safety and monitoring equipment must never be removed, bridged or disabled. 0020212888_01 vSMART Installation and maintenance instructions...
  • Page 14: Maintenance

    The original components of the product were also certified as part of the declaration of conformity. If you do not use cer- tified Vaillant original spare parts for maintenance or repair work, this voids the conformity of the product. We therefore strongly recommend that you fit Vaillant genuine spare parts.
  • Page 15: Appendix

    Approx. 2 years Level of protection IP20 Protection class Degree of contamination ≤ 50 ℃ Ambient temperature 7 … 30 ℃ Adjustable temperature range Transmission frequency 868 MHz for thermostat – commu- nication unit 0020212888_01 vSMART Installation and maintenance instructions...
  • Page 16: Technical Data - Communication Unit

    100 … 240 V Frequency 50/60 Hz Current consumption < 2 W Level of protection IP20 Protection class of the communication unit Protection class of the power supply Degree of contamination ≤ 50 ℃ Ambient temperature Installation and maintenance instructions vSMART 0020212888_01...
  • Page 17: Product Data In Accordance With Eu Ordinance No. 811/2013, 812/2013

    83 mm Depth 25 mm Product data in accordance with EU Ordinance no. 811/2013, 812/2013 Brand name Vaillant Model vSMART Temperature control class Contribution to the seasonal room-heat- 4,0 % ing energy efficiency ɳs 0020212888_01 vSMART Installation and maintenance instructions...
  • Page 18: App

    Apple's performance standards. Apple shall not be liable for the operation of this device or its compliance with the safety standards and regulations. Note that using this accessory with an iPhone may impair the radio performance. Installation and maintenance instructions vSMART 0020212888_01...
  • Page 20 Vaillant Ltd. Nottingham Road   Belper   Derbyshire   DE56 1JT Telephone 03 30 100‑34 61   Telephone (renewables) 02 07 022‑09 28 Vaillant Service Solutions 03 30 100‑31 43   Spares Technical Enquiries 177 359 66 15 info@vaillant.co.uk   technicalspares@groupservice.co.uk www.vaillant.co.uk © These instructions, or parts thereof, are protected by copyright and may be reproduced or distributed only with the manufac-...