Advertisement

Propane Construction Heater
RMC-LPC25DG/DGD/DGP/DGP-01 & LPC25
RMC-LPC80DG/DGD/DGP/DGP-01
RMC-LPC80C/L/L-01
RMC-LPC200L/DG/DGP/DGP-01
ANS Z83.7-2011 CSA 2.14-2011
Adequate ventilation must be provided.
CALIFORNIA PROPOSITION 65:
Fuels used in gas or oil fired appliances and the products of combustion of such fuels, contain chemicals known to
the State of California to cause cancer, birth defects or other reproductive harm. This product contains chemicals,
including lead and lead compounds, known to the State of California to cause cancer, birth defects or other
reproductive harm. Wash hands after handling.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768
C
US
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302
8:30 a.m. –
or email us at customerservice@ghpgroupinc.com
www.ghpgroupinc.com
www.ghpgroupinc.com.
(PROPANE, 25,000 BTU/hr)
(PROPANE, 80,000 BTU/hr)
(PROPANE, 80,000 BTU/hr)
(PROPANE, 200,000 BTU/hr)
4:30
pm CST, Monday – Friday
IMLPCDG - HCQ

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RMC-LPC25DG and is the answer not in the manual?

Questions and answers

Summary of Contents for Dyna-Glo RMC-LPC25DG

  • Page 1 Propane Construction Heater RMC-LPC25DG/DGD/DGP/DGP-01 & LPC25 (PROPANE, 25,000 BTU/hr) RMC-LPC80DG/DGD/DGP/DGP-01 (PROPANE, 80,000 BTU/hr) RMC-LPC80C/L/L-01 (PROPANE, 80,000 BTU/hr) RMC-LPC200L/DG/DGP/DGP-01 (PROPANE, 200,000 BTU/hr) ANS Z83.7-2011 CSA 2.14-2011 Adequate ventilation must be provided. GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302...
  • Page 3 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! RMC-LPC25Series / RMC-LPC80 Series........RMC-LPC200 Series....Illustration RMC-LPC25 Series..............Illustration RMC-LPC80 Series..............Illustration RMC-LPC200 Series..............WARNING : Using this heater in a residential garage requires that the heater is positioned so that it is protected against any possible damage by a moving vehicle, etc.
  • Page 4 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! (lb/h) Minimum Maximum Maximum Minimum 1.16 .196 11.7 x 12.87 LPC25 Series (0.53 kg/h) (4.98 mm) (0.32 kg/h) (29.69 x 32.79 cm) 3.71 .196 2.32 15.9 x 18.3 LPC80 Series (1.68 kg/h) (4.98 mm) (1.05 kg/h) (40.41 x 46.99 cm) 9.28...
  • Page 5 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! (100 lb.) 60 °F (15.56 °C) 40 °F (4.44 °C) 32 °F (0 °C) 20 °F (-6.67 °C) 10 °F (-12.22 °C) 0 °F (-17.78 °C) WARNING: Provide at least a 2½ square feet (.23 square meters) opening of fresh, outside air while running heater.
  • Page 6 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Assembly Time: 10 minutes Contents All Models: Unit, Manual, Hose and Regulator Assembly LPC80 and 200 Series Include: Upper Shell, Lower Shell and Hardware Kit With Screws (8) Tools Required for Assembly All Models: Adjustable Wrench LPC80 and LPC200 Series: Phillips head screwdriver Slide upper shell assembly up and off lower shell.
  • Page 7 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 11. Check all connections for leaks. Apply mixture of liqud soap and water to gas joints. Bubbles forming show a leak that must be corrected before using the heater. Turn propane supply valve on by turning tank valve counterclockwise If flame burner goes out, wait 5 minutes then repeat steps 4 and 5.
  • Page 8 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Fully open the valve on the propane cylinder counter clockwise and wait 15 seconds before proceeding to step 2. RMC-LPC25/80/200 Propane Convection Heater gap is .196” (4.98 mm). Check wire lead for damage. For Technical Support or Troubleshooting, Call: 1-877-447-4768 www.ghpgroupinc.com...
  • Page 9 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Store propane tank(s) in safe manner. Refer to Chapter 5 of Standard for Storage and handling of Liquefied Petroleum Gases, ANSI/NFPA 58, and the Natural Gas and Propane Installation Code CSA B149.1. Follow all local codes.
  • Page 10 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Replacement Parts for RMC-LPC25 Series GS22-LPC25 Regulator & Hose Assy 10’ (3.05 m) KR10601-10-31 Regulator & Hose Assy 15’ (4.57 m) KR10601-15-31 For Technical Support or Troubleshooting, Call: 1-877-447-4768 www.ghpgroupinc.com...
  • Page 11 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Replacement Parts for RMC-LPC80 Series GS22-LPC80 Regulator & Hose Assy 10’ (3.05 m) GR109-10-31 Regulator & Hose Assy 15’ (4.57 m) GR109-15-31 For Technical Support or Troubleshooting, Call: 1-877-447-4768 www.ghpgroupinc.com...
  • Page 12 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Replacement Parts for RMC-LPC200 Series GQ01 GS16 Regulator & Hose Assy 10’ (3.05 m) GR108-10-25 Regulator & Hose Assy 15’ (4.57 m) GR108-15-25 For Technical Support or Troubleshooting, Call: 1-877-447-4768 www.ghpgroupinc.com...
  • Page 13 Warranty LIMITED WARRANTY: This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale (lifetime warranty for the brass nozzle burner only).
  • Page 14: Warranty Registration

    WARRANTY REGISTRATION IMPORTANT: We urge you to fill out your warranty registration card within fourteen (14) days of date of purchase. You can also register your warranty on the internet at www.ghpgroupinc.com. Complete the entire serial number. Retain this portion of the card for your records.

Table of Contents

Save PDF