Youjie YJ4600 User Manual

Youjie YJ4600 User Manual

Area-imaging
Hide thumbs Also See for YJ4600:
Table of Contents

Advertisement

Quick Links

YJ4600
Area-Imaging Scanner
User's Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the YJ4600 and is the answer not in the manual?

Questions and answers

Summary of Contents for Youjie YJ4600

  • Page 1 YJ4600 Area-Imaging Scanner User’s Guide ™...
  • Page 2 The information in this publication does not represent a commitment on the part of Youjie. Youjie shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnish- ing, performance, or use of this material.
  • Page 3 EN61000-3-3. In addition, complies to 2006/95/EC Low Voltage Directive, when shipped with recommended power supply. Youjie shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive.
  • Page 4 CB Scheme Certified to CB Scheme IEC 60950-1, Second Edition. Solids and Water Protection The Youjie 4600 has a rating of IP40, immunity of foreign particles and dripping water. Warning To reduce the possibility of heat-related injuries, avoid touching sec-...
  • Page 5 Required Safety Labels Compliance Markings information, Part Number, and Serial Number information...
  • Page 7: Table Of Contents

    Table of Contents Chapter 1 - Getting Started About This Manual ............1-1 Unpacking Your Device..........1-1 Connecting the Device ..........1-1 Connecting with USB ..........1-1 Connecting with Keyboard Wedge ......1-2 Reading Techniques ........... 1-3 Menu Bar Code Security Settings ....... 1-3 Setting Custom Defaults ..........
  • Page 8 Beeper Pitch – Error ..........3-3 Beeper Duration – Good Read ......3-3 LED – Good Read ..........3-4 Number of Beeps – Good Read ......3-4 Number of Beeps – Error ........3-4 Good Read Delay ..........3-5 User-Specified Good Read Delay......3-5 Manual Trigger Mode...........3-5 Presentation Mode............3-6 Presentation Sensitivity .........
  • Page 9 Chapter 5 - Data Formatting Data Format Editor Introduction ........5-1 Add a Data Format ............5-1 Other Programming Selections ......5-3 Terminal ID Table............5-4 Data Format Editor Commands ........5-4 Move Commands ..........5-5 Search Commands..........5-5 Miscellaneous Commands ........5-6 Data Formatter ............
  • Page 10 UPC-E1..............6-27 EAN/JAN-13 ..............6-27 ISBN Translate ............ 6-29 EAN/JAN-8 ..............6-30 MSI ................6-32 GS1 DataBar Omnidirectional ........6-34 GS1 DataBar Limited..........6-34 GS1 DataBar Expanded ..........6-35 Codablock A ..............6-36 Codablock F...............6-37 PDF417..............6-38 MacroPDF417............6-39 MicroPDF417.............6-39 GS1 Composite Codes ..........6-40 UPC/EAN Version..........6-40 GS1 Emulation............6-41 TCIF Linked Code 39 (TLC39) ........6-42 QR Code..............6-43 QR Code Page ............
  • Page 11 Show Scan Driver Revision......... 8-1 Show Software Revision ..........8-1 Show Data Format ............8-2 Test Menu ..............8-2 Chapter 9 - Product Specifications Youjie 4600 Scanner Product Specifications ....9-1 Standard Cable Pinouts ..........9-2 Keyboard Wedge........... 9-2 USB ............... 9-3 ................9-4 Chapter 10 - Maintenance Repairs ..............
  • Page 13: Chapter 1 - Getting Started

    Youjie 4600 area-imaging scanner. Product specifications, dimensions, warranty, and customer support information are also included. Youjie bar code scanners are factory programmed for the most common termi- nal and communications settings. If you need to change these settings, pro- gramming is accomplished by scanning the bar codes in this guide.
  • Page 14: Connecting With Keyboard Wedge

    Verify the scanner operation by scanning a bar code from the Sample Symbols in the back of this manual. The unit defaults to a USB PC Keyboard. Refer to page 2-2 for other USB terminal settings. Connecting with Keyboard Wedge A scanner can be connected between the keyboard and PC as a “keyboard wedge,”...
  • Page 15: Reading Techniques

    Menu Bar Code Security Settings Youjie scanners are programmed by scanning menu bar codes or by sending serial commands to the scanner. If you want to restrict the ability to scan menu codes, you can use the Menu Bar Code Security settings. Please contact the...
  • Page 16: Setting Custom Defaults

    Setting Custom Defaults You have the ability to create a set of menu commands as your own, custom defaults. To do so, scan the Set Custom Defaults bar code below before scannning the menu commands for your custom defaults. If a menu command requires scanning numeric codes from the back cover, then a Save code, that entire sequence will be saved to your custom defaults.
  • Page 17: Resetting The Factory Defaults

    Resetting the Factory Defaults This selection erases all your settings and resets the scanner to the original factory defaults. It also disables all plugins . If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want to restore the scanner to factory default set- tings, first scan the Remove Custom Defaults bar code, then scan Activate Defaults.
  • Page 18 1 - 6...
  • Page 19: Chapter 2 - Programming The Interface

    Programming the Interface Introduction This chapter describes how to program your system for the desired interface. Programming the Interface - Plug and Play Plug and Play bar codes provide instant scanner set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect.
  • Page 20: Usb Ibm Surepos

    USB IBM SurePos Scan one of the following “Plug and Play” codes to program the scanner for an IBM SurePos (USB handheld scanner) or IBM SurePos (USB tabletop scanner) interface. Note: After scanning one of these codes, you must power cycle the cash register.
  • Page 21: Usb Hid

    USB HID Scan the following code to program the scanner for USB HID bar code scan- ners. USB HID Bar Code Scanner 2 - 3...
  • Page 22: Keyboard Country Layout

    Keyboard Country Layout Scan the appropriate country code below to program the keyboard layout for your country or language. As a general rule, the following characters are sup- ported, but need special care for countries other than the United States: @ | $ # { } [ ] = / ‘...
  • Page 23 Keyboard Country (continued) Brazil (MS) Bulgaria (Cyrillic) Bulgaria (Latin) Canada (French legacy) Canada (French) Canada (Multilingual) Croatia Czech Czech (Programmers) Czech (QWERTY) Czech (QWERTZ) Denmark Dutch (Netherlands) 2 - 5...
  • Page 24 Keyboard Country (continued) Estonia Faeroese Finland France Gaelic Germany Greek Greek (220 Latin) Greek (220) Greek (319 Latin) Greek (319) Greek (Latin) Greek (MS) 2 - 6...
  • Page 25 Keyboard Country (continued) Greek (Polytonic) Hebrew Hungarian (101 key) Hungary Iceland Irish Italian (142) Italy Japan ASCII Kazakh Kyrgyz (Cyrillic) Latin America Latvia 2 - 7...
  • Page 26 Keyboard Country (continued) Latvia (QWERTY) Lithuania Lithuania (IBM) Macedonia Malta Mongolian (Cyrillic) Norway Poland Polish (214) Polish (Programmers) Portugal Romania Russia 2 - 8...
  • Page 27 Keyboard Country (continued) Russian (MS) Russian (Typewriter) Serbia (Cyrillic) Serbia (Latin) Slovakia Slovakia (QWERTY) Slovakia (QWERTZ) Slovenia Spain Spanish variation Sweden Switzerland (French) 2 - 9...
  • Page 28: Keyboard Style

    Keyboard Country (continued) Switzerland (German) Tatar Turkey F Turkey Q Ukrainian United Kingdom United Stated (Dvorak right) United States (Dvorak left) United States (Dvorak) United States (International) Uzbek (Cyrillic) Keyboard Style This programs keyboard styles, such as Caps Lock and Shift Lock. If you have used Keyboard Conversion settings, they will override any of the following Key-...
  • Page 29 Regular is used when you normally have the Caps Lock key off. * Regular Caps Lock is used when you normally have the Caps Lock key on. Caps Lock Shift Lock is used when you normally have the Shift Lock key on (not common to U.S.
  • Page 30: Keyboard Conversion

    Emulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent). Emulate External Keyboard Note: After scanning the Emulate External Keyboard bar code, you must power cycle your computer. Keyboard Conversion Alphabetic keyboard characters can be forced to be all upper case or all lower- case.
  • Page 31: Keyboard Modifiers

    Default = Off. Control Character Output On * Control Character Output Off Keyboard Modifiers This modifies special keyboard features, such as CTRL+ ASCII codes and Turbo Mode. Control + ASCII Mode On: The scanner sends key combinations for ASCII control characters for values 00-1F. Windows is the preferred mode. All key- board country codes are supported.
  • Page 32 Turbo Mode: The scanner sends characters to a terminal faster. If the termi- nal drops characters, do not use Turbo Mode. Default = Off Turbo Mode On * Turbo Mode Off Numeric Keypad Mode: Sends numeric characters as if entered from a numeric keypad.
  • Page 33: Chapter 3 - Input/Output Settings

    Input/Output Settings Power Up Beeper The scanner can be programmed to beep when it’s powered up. Scan the Off bar code(s) if you don’t want a power up beep. Default = Power Up Beeper On - Scanner. Power Up Beeper Off - Scanner * Power Up Beeper On - Scanner...
  • Page 34: Good Read And Error Indicators

    Good Read and Error Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = Beeper - Good Read On.
  • Page 35: Beeper Pitch - Good Read

    Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the scan- ner emits on a good read. Default = Medium. Low (1600 Hz) * Medium (2400 Hz) High (4200 Hz) Beeper Pitch – Error The beeper pitch codes modify the pitch (frequency) of the sound the scan- ner emits when there is a bad read or error.
  • Page 36: Led - Good Read

    LED – Good Read The LED indicator can be programmed On or Off in response to a good read. Default = On. * LED - Good Read On LED - Good Read Off Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read.
  • Page 37: Good Read Delay

    Good Read Delay This sets the minimum amount of time before the scanner can read another bar code. Default = 0 ms (No Delay). * No Delay Short Delay (500 ms) Medium Delay (1,000 ms) Long Delay (1,500 ms) User-Specified Good Read Delay If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save.
  • Page 38: Presentation Mode

    Presentation Mode Presentation Mode uses ambient light to detect bar codes. The LED dims until a bar code is presented to the scanner, then the LED brightens to read the code. If the light level in the room is not high enough, Presentation Mode may not work properly.
  • Page 39 In the example below, the white box is the centering window. The centering window has been set to 20% left, 30% right, 8% top, and 25% bottom. Since Bar Code 1 passes through the centering window, it will be read. Bar Code 2 does not pass through the centering window, so it will not be read.
  • Page 40: Mobile Phone Read Mode

    Scan Presentation Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual.
  • Page 41: Hands Free Time-Out

    Hands Free Time-Out The Scan Stand and Presentation Modes are referred to as “hands free” modes. If the scanner’s button is pressed when using a hands free mode, the scanner changes to manual trigger mode. You can set the time the scanner should remain in manual trigger mode by setting the Hands Free Time-Out.
  • Page 42: User-Specified Reread Delay

    User-Specified Reread Delay If you want to set your own length for the reread delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. User-Specified Reread Delay Scanner Time-Out Scanner Time-Out powers down the scanner after the unit has been idle for the specified time.
  • Page 43 In the example below, the white box is the centering window. The centering win- dow has been set to 20% left, 30% right, 8% top, and 25% bottom. Since Bar Code 1 passes through the centering window, it will be read. Bar Code 2 does not pass through the centering window, so it will not be read.
  • Page 44: No Read

    Scan Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual.
  • Page 45: Video Reverse

    Video Reverse Video Reverse is used to allow the scanner to read bar codes that are inverted. The Video Reverse Off bar code below is an example of this type of bar code. Scan Video Reverse Only to read only inverted bar codes. Scan Video Reverse and Standard Bar Codes to read both types of codes.
  • Page 46: Working Orientation

    Working Orientation Some bar codes are direction-sensitive. For example, KIX codes and OCR can misread when scanned sideways or upside down. Use the working orientation settings if your direction-sensitive codes will not usually be presented upright to the scanner. Default = Upright. Upright: Vertical, Top to Bottom: (Rotate CW 90°)
  • Page 47: Chapter 4 - Data Editing

    Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string.
  • Page 48: To Clear One Or All Prefixes Or Suffixes

    symbology to which you want to apply the prefix or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”. Step 3. Scan the 2 hex digits from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies. Step 4.
  • Page 49: To Add A Carriage Return Suffix To All Symbologies

    Step 1. Scan the Clear One Prefix or Clear One Suffix symbol. Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Symbology Chart, beginning on page A-1) for the symbology from which you want to clear the prefix or suffix. Step 3.
  • Page 50: Suffix Selections

    Suffix Selections Add Suffix Clear One Suffix Clear All Suffixes Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page...
  • Page 51: Intercharacter Delay

    Intercharacter Delay An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each character of scanned data. Scan the Intercharacter Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual.
  • Page 52: Interfunction Delay

    Interfunction Delay An interfunction delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each segment of the message string. Scan the Interfunction Delay bar code below, then scan the num- ber of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual.
  • Page 53: Data Format Editor Introduction

    Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For exam- ple, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output.
  • Page 54 you are programming. (See Primary/Alternate Data Formats on page 5-8 for further information.) Step 3. Terminal Type Refer to Terminal ID Table (page 5-4) and locate the Terminal ID number for your PC. Scan three numeric bar codes on the inside back cover to program the scanner for your terminal ID (you must enter 3 digits).
  • Page 55: Other Programming Selections

    Other Programming Selections Clear One Data Format This deletes one data format for one symbology. If you are clearing the primary format, scan 0 from the Programming Chart inside the back cover of this manual. If you are clearing an alternate format, scan 1, 2, or 3, depending on the format you are clearing.
  • Page 56: Terminal Id Table

    Terminal ID Table Terminal Terminal Model(s) PC/AT and compatibles USB SurePOS Handheld Scanner USB SurePOS Tabletop Scanner PC Keyboard Mac Keyboard Japanese Keyboard (PC) HID POS Data Format Editor Commands Send Commands Send all characters F1 Include in the output message all of the characters from the input message, starting from current cursor position, followed by an insert character.
  • Page 57: Move Commands

    Send all but the last characters E9 Include in the output message all but the last “nn” characters, starting from the current cursor position. The cursor is moved forward to one position past the last input message character included. Syntax = E9nn where nn stands for the numeric value (00-99) for the number of characters that will not be sent at the end of the message.
  • Page 58: Miscellaneous Commands

    Search backward for a character F9 Search the input message backward for “xx” character from the current cursor position, leaving the cursor pointing to the “xx” character. Syntax = F9xx where xx stands for the search character’s hex value for its ASCII code.
  • Page 59: Data Formatter

    Stop replacing characters E5 Terminates character replacement. Syntax = E5. Compare characters FE Compare the character in the current cursor position to the character “xx.” If characters are equal, move the cursor forward one position. Syntax = FExx where xx stands for the comparison character’s hex value for its ASCII code.
  • Page 60: Primary/Alternate Data Formats

    Default = Data Formatter On, Not Required, Keep Prefix/Suffix. * Data Formatter On, Not Required, Keep Prefix/Suffix Data Format Required, Keep Prefix/Suffix Primary/Alternate Data Formats You can save up to four data formats, and switch between these formats. Your primary data format is saved under 0. Your other three formats are saved under 1, 2, and 3.
  • Page 61 Symbologies This programming section contains the following menu selections. • All Symbologies • Interleaved 2 of 5 • Aztec Code • Korea Post • China Post (Hong Kong 2 of 5) • Matrix 2 of 5 • Chinese Sensible (Han Xin) Code •...
  • Page 62: All Symbologies

    All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On symbol for that particular symbology.
  • Page 63: Codabar

    Codabar <Default All Codabar Settings> Codabar On/Off * On Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit . Transmit * Don’t Transmit Codabar Check Character Codabar check characters are created using different “modulos.”...
  • Page 64: Codabar Concatenation

    When Check Character is set to Validate, but Don’t Transmit , the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. * No Check Character Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit...
  • Page 65: Codabar Message Length

    Codabar Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. Minimum Message Length Maximum Message Length 6 - 5...
  • Page 66: Code 39

    Code 39 < Default All Code 39 Settings > Code 39 On/Off * On Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.
  • Page 67: Code 39 Message Length

    When Check Character is set to Validate and Transmit, the scanner only reads Code 39 bar codes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check Charac- ter. * No Check Character Validate, but Don’t Transmit Validate and Transmit...
  • Page 68: Full Ascii

    acter(s), it buffers Code 39 bar codes until it reads a Code 39 bar code that does not have the append trigger. The data is then transmitted in the order in which the bar codes were read (FIFO). Default = Off. * Off Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within...
  • Page 69: Code 39 Code Page

    Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9. Full ASCII On * Full ASCII Off Code 39 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting.
  • Page 70: Interleaved 2 Of 5

    Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > Interleaved 2 of 5 On/Off * On Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.
  • Page 71: Interleaved 2 Of 5 Message Length

    Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length NEC 2 of 5...
  • Page 72 When Check Digit is set to Validate and Transmit, the scanner only reads NEC 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit. * No Check Digit Validate, but Don’t Transmit Validate and Transmit...
  • Page 73: Code 93 Message Length

    Code 93 < Default All Code 93 Settings > Code 93 On/Off * On Code 93 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80.
  • Page 74: Code 93 Code Page

    which the bar codes are read, deleting the first space from each. The scanner transmits the appended data when it reads a Code 93 bar code that starts with a character other than a space. Default = Off. * Off Code 93 Code Page Code pages define the mapping of character codes to characters.
  • Page 75: Straight 2 Of 5 Industrial (Three-Bar Start/Stop)

    Straight 2 of 5 Industrial (three-bar start/stop) <Default All Straight 2 of 5 Industrial Settings> Straight 2 of 5 Industrial On/Off * Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information.
  • Page 76: Straight 2 Of 5 Iata (Two-Bar Start/Stop)

    Straight 2 of 5 IATA (two-bar start/stop) <Default All Straight 2 of 5 IATA Settings> Straight 2 of 5 IATA On/Off * Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information.
  • Page 77: Matrix 2 Of 5

    Matrix 2 of 5 <Default All Matrix 2 of 5 Settings> Matrix 2 of 5 On/Off * Off Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-80.
  • Page 78: Code 128

    Code 128 <Default All Code 128 Settings> Code 128 On/Off * On ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood information in a uniform manner. The use of ISBT formats requires a paid license. The ISBT 128 Application Specification describes 1) the critical data elements for labeling blood prod- ucts, 2) the current recommendation to use Code 128 due to its high degree of security and its space-efficient design, 3) a variation of Code 128...
  • Page 79: Code 128 Code Page

    Code 128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 128 Append This function allows the scanner to append the data from several Code 128...
  • Page 80: Gs1-128

    GS1-128 <Default All GS1-128 Settings> GS1-128 On/Off * On GS1-128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-80. Minimum Default = 1, Maximum Default = 80.
  • Page 81: Upc-A

    UPC-A <Default All UPC-A Settings> UPC-A On/Off * On Note: When UPC-A Off is scanned, UPC-A bar codes are transmitted as EAN- UPC-A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On . * On 6 - 21...
  • Page 82 UPC-A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. * On UPC-A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data.
  • Page 83: Upc-A/Ean-13

    UPC-A Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On. * On UPC-A/EAN-13 with Extended Coupon Code Use the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code.
  • Page 84: Coupon Gs1 Databar Output

    Coupon GS1 DataBar Output If you scan coupons that have both UPC and GS1 DataBar codes, you may wish to scan and output only the data from the GS1 DataBar code. Scan the GS1 Output On code below to scan and output only the GS1 DataBar code data.
  • Page 85 UPC-E0 Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off. * Off UPC-E0 Addenda Required When Required is scanned, the scanner will only read UPC-E bar codes that have addenda. Default = Not Required. Required * Not Required UPC-E0 Addenda Separator...
  • Page 86 UPC-E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On UPC-E0 Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it.
  • Page 87: Upc-E1

    UPC-E1 Most U.P.C. bar codes lead with the 0 number system. For these codes, use UPC-E0 (page 6-24). If you need to read codes that lead with the 1 number system, use the UPC-E1 On selection. Default = Off. UPC-E1 On * UPC-E1 Off EAN/JAN-13 <Default All EAN/JAN Settings>...
  • Page 88 EAN/JAN-13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data.
  • Page 89: Isbn Translate

    EAN/JAN-13 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space. Default = On. * On Note: If you want to enable or disable EAN13 with Extended Coupon Code, refer to UPC-A/EAN-13 with Extended Coupon Code (page 6-23).
  • Page 90: Ean/Jan-8

    EAN/JAN-8 <Default All EAN/JAN-8 Settings> EAN/JAN-8 On/Off * On EAN/JAN-8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On 6 - 30...
  • Page 91 EAN/JAN-8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-8 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-8 bar...
  • Page 92: Msi

    <Default All MSI Settings> MSI On/Off * Off MSI Check Character Different types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check charac- ters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Validate Type 10/11 and Transmit, the scanner will only read MSI bar codes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned...
  • Page 93: Msi Message Length

    When Check Character is set to Validate Type 10/11, but Don’t Transmit, the unit will only read MSI bar codes printed with the specified type check character(s), but will not transmit the check character(s) with the scanned data. * Validate Type 10, but Don’t Transmit Validate Type 10 and Transmit Validate 2 Type 10 Characters,...
  • Page 94: Gs1 Databar Omnidirectional

    GS1 DataBar Omnidirectional < Default All GS1 DataBar Omnidirectional Settings > GS1 DataBar Omnidirectional On/Off * On GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > GS1 DataBar Limited On/Off * On 6 - 34...
  • Page 95: Gs1 Databar Expanded

    GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > GS1 DataBar Expanded On/Off * On GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 4-74.
  • Page 96: Codablock A

    Codablock A <Default All Codablock A Settings> Codablock A On/Off * Off Codablock A Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-600. Minimum Default = 1, Maximum Default = 600.
  • Page 97: Codablock F

    Codablock F <Default All Codablock F Settings> Codablock F On/Off * Off Codablock F Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048.
  • Page 98: Pdf417

    PDF417 < Default All PDF417 Settings > PDF417 On/Off * On PDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750.
  • Page 99: Macropdf417

    MacroPDF417 MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 bar codes. When this selection is enabled, these multiple bar codes are assembled into a single data string. Default = On. * On MicroPDF417 <...
  • Page 100: Gs1 Composite Codes

    MicroPDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366. Minimum Message Length Maximum Message Length GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a...
  • Page 101: Gs1 Emulation

    GS1 Composite Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-2435. Minimum Default = 1, Maximum Default = 2435. Minimum Message Length Maximum Message Length GS1 Emulation...
  • Page 102: Tcif Linked Code 39 (Tlc39)

    Default = GS1 Emulation Off . GS1-128 Emulation GS1 DataBar Emulation GS1 Code Expansion Off EAN8 to EAN13 Conversion * GS1 Emulation Off TCIF Linked Code 39 (TLC39) This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component.
  • Page 103: Qr Code

    QR Code < Default All QR Code Settings > QR Code On/Off This selection applies to both QR Code and Micro QR Code. * On QR Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information.
  • Page 104: Qr Code Page

    information encoded in those bar codes. Once the proper number of codes is reached, the data is output in the order specified in the bar codes. Default = On. * On QR Code Page QR Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting.
  • Page 105: Data Matrix

    Data Matrix < Default All Data Matrix Settings > Data Matrix On/Off * On Data Matrix Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116.
  • Page 106: Data Matrix Code Page

    mined by information encoded in those bar codes. Once the proper num- ber of codes is reached, the data is output in the order specified in the bar codes. Default = On. * On Data Matrix Code Page Data Matrix Code pages define the mapping of character codes to charac- ters.
  • Page 107: Aztec Code

    Aztec Code < Default All Aztec Code Settings > Aztec Code On/Off * On Aztec Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-3832. Minimum Default = 1, Maximum Default = 3832.
  • Page 108: Aztec Code Page

    ter(s), it buffers the number of Aztec bar codes determined by information encoded in those bar codes. Once the proper number of codes is reached, the data is output in the order specified in the bar codes. Default = Off. * Off Aztec Code Page Aztec Code pages define the mapping of character codes to characters.
  • Page 109: Chinese Sensible (Han Xin) Code

    Chinese Sensible (Han Xin) Code < Default All Han Xin Settings > Han Xin Code On/Off * Off Han Xin Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-7833.
  • Page 110 China Post (Hong Kong 2 of 5) On/Off * Off China Post (Hong Kong 2 of 5) Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maxi- mum Default = 80.
  • Page 111: Korea Post

    Korea Post <Default All Korea Post Settings> Korea Post * Off Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maxi- mum Default = 48.
  • Page 112 6 - 52...
  • Page 113: Chapter 7 - Interface Keys

    Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Refer to page 2-13 enable Control + ASCII mode. Function Code HEX/ASCII Value Full ASCII “CTRL”...
  • Page 114 The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US only. The following chart indicates the equivalents of these five characters for different countries. Country Codes United States Belgium < Scandinavia <...
  • Page 115: Supported Interface Keys

    Supported Interface Keys IBM PC/AT and Compatibles, Apple Mac/iMac ASCII USB PC Supported Keys Keyboard Reserved Reserved Enter (KP) Enter/Numpad Enter Cap Lock CAPS ALT make ALT make ALT break ALT break CTRL make CNTRL make CTRL break CNTRL break CR/Enter RETURN Reserved...
  • Page 116 7 - 4...
  • Page 117: Chapter 8 - Utilities

    Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart, beginning on page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D.
  • Page 118: Show Data Format

    Show Data Format Scan the bar code below to show current data format settings. DFMBK3?. Data Format Settings Test Menu When you scan the Test Menu On code, then scan a programming code in this manual, the scanner displays the content of a programming code. The pro- gramming function will still occur, but in addition, the content of that program- ming code is output to the terminal.
  • Page 119: Chapter 9 - Product Specifications

    Product Specifications Youjie 4600 Scanner Product Specifications Parameter Specification Mechanical Height 2.9 inches (75mm) Length 6.7 inches (170mm) Width 2.6 inches (66mm) Weight 4.2 ounces (119g) Electrical Input Voltage 4 to 5.5VDC Operating Power 2W; 400 mA (typical) @ 5V Standby Power .45W;...
  • Page 120: Standard Cable Pinouts

    Standard Cable Pinouts Keyboard Wedge 9 - 2...
  • Page 121: Usb

    Standard Cable Pinouts 9 - 3...
  • Page 122 9 - 4...
  • Page 123: Chapter 10 - Maintenance

    Maintenance Repairs Repairs and/or upgrades are not to be performed on this product. These ser- vices are to be performed only by an authorized service center (see Customer Support on page 11-1). Maintenance Your device provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks ensure dependable operation: Cleaning the Device...
  • Page 124: Replacing An Interface Cable

    • Order replacement cables from Youjie or from an authorized distributor. • When ordering a replacement cable, specify the cable part number of the original interface cable. Replacing an Interface Cable 1. Turn the power to the host system OFF.
  • Page 125 • You need to program a suffix. Programming a suffix enables the scanner to output the bar code data plus the key you need (such as “CR”) to enter the data into your application. Refer to Prefix/Suffix Overview beginning on page 4-1 for further information. Does the scanner read the bar code incorrectly? If the scanner reads a bar code, but the data is not displayed correctly on the host screen:...
  • Page 126 10 - 4...
  • Page 127: Chapter 11 - Customer Support

    (C) static electricity or electro-static dis- charge, (D) operation under conditions beyond the specified operating parame- ters, or (E) repair or service of the product by anyone other than Youjie or its authorized representatives. This warranty shall extend from the time of shipment for the duration published by Youjie for the product at the time of purchase ("Warranty Period").
  • Page 128 This includes but is not limited to: cables, power supplies, cradles, and docking stations. Youjie extends these warranties only to the first end-users of the products. These warranties are non-transferable. The duration of the limited warranty for the Youjie 4600 scanner is ninety (90)days. 11 - 2...
  • Page 129: Appendix A - Reference Charts

    Reference Charts Symbology Chart Possible AIM ID Code ID Symbology AIM ID Modifiers (hex) ( m ) All Symbologies (0x99) Australian Post A (0x41) ]z m Aztec Code 0-9, A-C z (0x7A) Batch Mode Quantity 5 (0x35) British Post B (0x42) Canadian Post C (0x43) China Post...
  • Page 130 Possible AIM ID Code ID Symbology AIM ID Modifiers (hex) ( m ) EAN-8 with Add-On D (0x44) GS1 Composite ]e m y (0x79) GS1 DataBar ]e m y (0x79) GS1 DataBar Limited ]e m { (0x7B) GS1 DataBar Omnidirectional ]e m y (0x79) GS1 DataBar Expanded...
  • Page 131 Possible AIM ID Code ID Symbology AIM ID Modifiers (hex) ( m ) TCIF Linked Code 39 (TLC39) T (0x54) Telepen ]B m t (0x54) UPC-A c (0x63) UPC-A with Add-On c (0x63) UPC-A with Extended c (0x63) Coupon Code UPC-E E (0x45) UPC-E with Add-On...
  • Page 132: Ascii Conversion Chart (Code Page 1252

    ASCII Conversion Chart (Code Page 1252 Note: This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings. Non-Printable Characters DEC HEX Character (Code) DEC HEX Character (Code) NULL DATA LINK ESCAPE (DLE) START OF HEADING DEVICE CONTROL 1 (DC1) (SOH)
  • Page 133 Printable Characters (Continued) DEC HEX Character DEC HEX Character DEC HEX Character < > <DEL> Extended ASCII Characters DEC HEX Character DEC HEX Character DEC HEX Character € € « Ö ¬ × ‚ Ø ƒ ® Ù „ ¯ Ú...
  • Page 134: Code Page Mapping Of Printed Bar Codes

    Extended ASCII Characters (Continued) DEC HEX Character DEC HEX Character DEC HEX Character Œ · â ¸ ã Ž ¹ ä º å » æ ‘ ¼ ç ’ ½ è “ ¾ é ” ¿ ê • À ë –...
  • Page 135 one the host program is expecting. If this is the case, select the code page with which the bar codes were created. The data characters should then appear properly. Code Page Standard Description CP ISO646 2 (Default) ISO 2022 Automatic National Replacement Characters CP Binary ISO 8859 1 51...
  • Page 136: Unicode Key Maps

    Unicode Key Maps 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 4B 50 55 5A 5F 64 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 4C 51 56 5B 60 65 1F 20 21 22 23 24 25 26 27 28 29...
  • Page 137 Sample Symbols UPC-A Interleaved 2 of 5 0 123456 7890 Code 128 1234567890 EAN-13 Code 128 Code 39 9 780330 290951 Codabar BC321 Code 93 A13579B Straight 2 of 5 Industrial 123456-9$ 123456...
  • Page 138 Sample Symbols Matrix 2 of 5 GS1 DataBar 6543210 PDF417 (01)00123456789012 Car Registration Data Matrix QR Code Test Symbol Numbers 4-CB (4-State Customer Bar Code) 01,234,567094,987654321,01234567891 ID-tag (UPU 4-State) J18CUSA8E6N062315014880T...
  • Page 139 Sample Symbols Aztec Micro PDF417 Package Label MaxiCode Test Message Test Message...
  • Page 140: Programming Chart

    Programming Chart...
  • Page 141 Programming Chart Save Discard Reset Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again.
  • Page 142 YG4600-UG Rev A 6/12...

Table of Contents

Save PDF