Installation & Operators Manual Installation & Operators Manual The Classeq Under Counter Range The Classeq Under Counter Range Glasswashers Dishwasher Glasswashers Dishwasher Eco 1 Hydro 400 Eco 2 Hydro 700 Eco 3 Hydro 750 Duo 2 Duo 400 Duo 3...
Installation should only be carried out by a ‘Classeq’ approved technician, and in accordance with current regulations and within our instructions. Modification : ‘Classeq’ reserves the right to modify either the appliance or the contents of these instructions without notice. Operation : The appliance should only be used by a trained operator as instructed in section 5 of this manual.
Page 5
If the supply cable is damaged, it must be replaced by a cable or cord assembly supplied by Classeq, or its service agents, or to the following minimum specification. Machine rating Cable type Temp.
Page 6
3.3.1 Electrical rating : Within the ‘Classeq’ range several of the 500mm² basket appliances can be either down rated or up rated electrically, such a procedure MUST be carried out by a ‘Classeq’ approved technician. The down / up rating of the machine is carried out by configuring the terminal block within the appliance to the following 13 Amp –...
Page 7
If you have any doubts about the drainage system on the machine, please either contact Classeq or your dealer / agent FOR ADVISE on technical enquires, please contact : Technical support tech.support@classeq.co.uk...
40° C. For more information, please contact : Sales 0844 2245 249 sales@classeq.co.uk 4.1.1 Priming of Rinse aid & Detergent : This procedure is only required when commissioning the machine and not in normal operation Ensure the machine is empty of water •...
Page 9
Dishwashers 80° c Demonstration : ‘Classeq’ recommends that prior to leaving the site / installation, the installer demonstrates the following to the end user, as this will ensure the appliance is correctly used What to do in case of an emergency, i.e. how to isolate the mains •...
Appliances fitted with a drain pump, the Cycle switch and lamp double as the drain down switch and lamp If in doubt please contact ’Classeq’ for advise. Please contact Classeq Technical for advice and assistance : Technical support tech.support@classeq.co.uk Page 8...
Page 11
Switch the machine on : Ensure that both the water and electrical supply are connected and switched on, then depress the ‘ON/OFF’ switch located on the fascia of the machine. The machine will now automatically fill and heat, during this process the door should remain closed, allowing the process to be completed quickly.
Page 12
DO NOT switch isolate the appliance while in the drain down cycle. Note ! Once empty ‘Classeq’ recommends that the mains water and electricity supplies are isolated at the wall and the machine be cleaned as instructed in section 6 of this manual...
Cleaning Cleaning Prior to cleaning : Switch off and isolated electrical supply before cleaning the appliance WARNING DO NOT use cleaning agents that contain CHLORINE, BLEACH or HYPOCHLORITE. DO NOT use STEEL WOOL, WIRE BRUSHES or any other abrasive materials. DO NOT jet wash or hose pipe the appliance down either internally or on the exterior Internal cleaning :...
Once dry, clean using a STAINLESS STEEL cleaning agent If you wish to purchase stainless steel cleaning agent, please contact : Spares 0844 2245 252 spares@classeq.co.uk Trouble shooting Trouble shooting Before placing a service call , please check the following: •...
Page 15
Appliance fills slowly : Check water supply tap is fully open. • Check water supply pressure, should be above 2 bar, if not ask • your dealer to install a booster pump to increase water pressure. Check and clean rinse jets (located on the wash arms within the •...
Page 16
Will not switch OFF : Isolate at mains electricity before calling for a service technician • immediately. If you still require service, please contact : Service 0844 2245 245 service@classeq.co.uk Technical support or for tech.support@classeq.co.uk Page 14...
If for any reason you require to remove or, de-commission your appliance, then do so in accordance with local and national regulations. As a minimum ‘Classeq’ recommends the following procedure is followed. Remove chemical tubes from the chemical bottles, ensuring bottles •...
Page 18
Air pressure switch 530.0004 (Gravity) 3 pole relay CONT/30 4 pole contactor CONTACTOR/4 If you wish to order any of the parts for your Classeq machine please contact our Spares Parts Department. Spares 0844 2245 252 0870 224 7153 spares@classeq.co.uk A comprehensive parts manual is available on the Classeq website: www.classeq.co.uk...