AKT 352
GB
1
2
5
LIGHTING THE BURNERS
To ignite one of the burners, turn the relative knob anticlockwise to the maximum flame setting
Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This safety device shuts off the gas if the flame goes out accidentally (draughts, interruption of gas, liquids boiling over,
etc.).
The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
-
The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For optimum burner performance, observe the following
rules:
-
Use pots and pans that fit the burners (see table on the
right).
-
Only use flat-bottomed pots and pans.
-
Use the correct amount of water for cooking foods and
keep the pot covered.
5019 319 01501
PRODUCT DESCRIPTION SHEET
Removable grid(s)
1.
3
Semi-rapid burner
2.
Rapid burner
3.
Semi-rapid burner control knob
4.
Rapid burner control knob
5.
SYMBOLS
Tap closed
Max. flame
Min. flame
4
Burner
Pot Ø
Rapid
from 24 to 26 cm
Semi-rapid
from 16 to 22 cm
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
.
NOTE: In the event a hood is fitted above the cooktop, please refer to the hood instructions for the correct
distance.
INJECTOR TABLE
Type of gas used
Type of
burner
NATURAL GAS
rapid
(Methane)
G20
semi-rapid
LIQUEFIED
PETROLEUM GAS
rapid
(Butane)
G30
semi-rapid
(Propane)
G31
Type of gas used
Model configuration
G20 20 mbar
2 burners
G30-G31 30 mbar
2 burners
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Injector
Nominal heating
Nominal
Reduced
marking
capacity
consumption
heating capacity
kW
kW
128
3.00
286 l/h
95
1.65
157 l/h
87
3.00
218 g/h
67
1.65
120 g/h
Nominal heating capacity
Total nominal
kW
consumption
4.65
443 l/h
4.65
338 g/h
CZ SK
CATEGORY II2H3B/P
Gas pressure (mbar)
min.
nom.
max.
0.60
17
20
25
0.35
0.60
20
30
35
0.35
3
Air necessary (m
) for the
3
combustion of 1 m
of gas
9.52
30.94

Advertisement

loading

Summary of Contents for Whirlpool AKT 352

  • Page 1 AKT 352 PRODUCT DESCRIPTION SHEET CZ SK Removable grid(s) DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm) Semi-rapid burner Rapid burner Semi-rapid burner control knob Rapid burner control knob SYMBOLS Tap closed Max. flame Min. flame LIGHTING THE BURNERS • To ignite one of the burners, turn the relative knob anticlockwise to the maximum flame setting •...
  • Page 2 20 mm from the bottom of the hob. If there is an oven beneath the hob, make sure that it is manufactured by Whirlpool and equipped with a cooling system. The SAFEGUARDING THE ENVIRONMENT manufacturer declines all liability if another brand oven is installed beneath the hob.
  • Page 3 INSTALLATION GAS CONNECTION • The gas supply system must comply with local regulations. • You can find specific local regulations for some countries in the paragraph “Reference to Local Regulations”. If no information concerning your Country is given, please ask details to your Installer. •...
  • Page 4: Troubleshooting Guide

    Manufacturer: Note: to avoid damaging the electric ignition device, do not use it when the burners are not in their housing. Whirlpool Europe S.r.l. Viale G. Borghi, 27 21025 Comerio (VA)