  • Page 1: Power Supply Unit

    Line-Interactive Uninterruptible Power Supply Unit 2kVATower Model (203T) USER’S MANUAL MNL105-203T Version 1.0 Powering Life...
  • Page 2 Follow all instructions, warnings, and cautions listed in this manual. Failure to do so may cause injury or product damage not covered by the warranty. Applying information contained in this manual to any other product may cause injury. The INTegral is registered for sale by Power Innovations International, Inc. Version 1.0 © Copyright 2015.
  • Page 3: Table Of Contents

    8.1.3.1—Previous Service ............................. 25 8.1.3.2—Misuse or Abuse.............................. 25 8.1.3.3—Non-Transferable ............................25 8.2—Warranty Claims ................................26 8.2.1—Proof of Purchase ..............................26 8.2.2—Notifying Power Innovations ..........................26 8.2.3—Product Shipping ..............................26 8.24—Prior Approval ................................. 26 8.3—Limitation of Remedies ..............................26 8.3.1—Indirect Damages ..............................26 8.4—Customer Service .................................
  • Page 4 This page intentionally left blank.
  • Page 5: Key Features

    Detachable dot-matrix LCD panel  Compact size  Intelligent fan speed control  Cold Start Note It is possible to have one (1) additional feature included on the INTegral, while others are not included. INTegral Line-Interactive Uninterruptible Power Supply Unit—2kVA-T Power Innovations...
  • Page 6: Using This Manual

    Bold type—Used to reference figures or other chapters or sections. Blue, Underlined type—Used for PDF viewing. The inclusive text is a hyperlink to be accessed by pressing the control button (CTRL) and clicking on the text. Power Innovations INTegral Line-Interactive Uninterruptible Power Supply—2kVA-T...
  • Page 7: Power Flow

    In the battery charging loop (Figure 2), an AC/DC converter changes AC utility input voltage into DC power, which charges the unit’s batteries. Figure 2: Power Flow in Normal Mode INTegral Line-Interactive Uninterruptible Power Supply Unit—2kVA-T Power Innovations...
  • Page 8: 2-Battery Backup Mode

    Actual backup time will vary, depending upon initial battery charge and current load percentage. Manual Helps See 6—Specifications for backup time estimates. Figure 3: Power Flow in Battery Backup Mode Power Innovations INTegral Line-Interactive Uninterruptible Power Supply—2kVA-T...
  • Page 9: Receiving

    Save the original packaging and use it for transport. Using the correct packaging will prevent unnecessary harm to the unit. Note With concerns about the manufacture or shipping of this product or its components, please contact: Power Innovations International, Inc. Tel: (801) 785-4123 Fax: (801) 785-6999 E-mail: service@power-innovations.com...
  • Page 10 This page intentionally left blank.
  • Page 11: Selecting An Operating Environment

    Since the letter following this model number is a T, this model is meant to operate exclusively in tower configuration. To correctly place a tower unit, set it on its vertical bottom end. INTegral Line-Interactive Uninterruptible Power Supply Unit—2kVA-T Power Innovations...
  • Page 12: Connecting Units

    Connect the monitoring UPQsoft cord to the USB port or install the UPQNet-Agent9 Mini. After the hardware has been connected to the port, the monitoring software is ready to be connected to a computer and configured. Power Innovations INTegral Line-Interactive Uninterruptible Power Supply—2kVA-T...
  • Page 13: Prestart Checklist

     The devices to be powered are OFF.  The rated input voltage from the wall socket falls within the unit’s safe operating range.  Connected cables are placed carefully to prevent stepping/tripping hazards. INTegral Line-Interactive Uninterruptible Power Supply Unit—2kVA-T Power Innovations...
  • Page 14 This page intentionally left blank.
  • Page 15: Operating Cautions

    Keep objects from within four (4) inches on all visible ventilation holes in the UPS. The added space helps the unit ventilate. Keep the UPS far away from sources of heat (for example, heaters or direct sunlight). Keep the load within the correct operating range. INTegral Line-Interactive Uninterruptible Power Supply Unit—2kVA-T Power Innovations...
  • Page 16: Keys And Indicators

    Fault LED—Red LED that indicates the UPS is in fault condition. Problems, such as an abnormal inverter or over-temperature DC voltage, need to be solved. These conditions will likely require the assistance of a Power Innovations Service Representative. Warning LED—Yellow LED that indicates the status of the UPS should be watched carefully. Some Warning circumstances include UPS overload or battery-backup mode.
  • Page 17: 1-Basic Operations

    Below, see diagrams of all menus. For information about selecting options with the menus, see 8.1—Keys and Indicators. Note The menus below are based on the 220V system. For the 110V system, the menus are the same as the 220V system, but the voltage numbers will be different. INTegral Line-Interactive Uninterruptible Power Supply Unit—2kVA-T Power Innovations...
  • Page 18 Rated Specification Menu Status Menu Voltage Menu Frequency Menu Power Innovations INTegral Line-Interactive Uninterruptible Power Supply—2kVA-T...
  • Page 19 Old Rec indicates issues occurring during the previous uptime. AC Fail indicates events during which the system has gone into backup mode. OV Load indicates that the system has gone into overload condition. INTegral Line-Interactive Uninterruptible Power Supply Unit—2kVA-T Power Innovations...
  • Page 20: Rs-232 Computer Interface Port

    UPS. 4.5.1—DB9 Pin Assignment PIN 2: RS-232 RXD PIN 3: RS-232 TXD PIN 5: GND The other pins have no function. Power Innovations INTegral Line-Interactive Uninterruptible Power Supply—2kVA-T...
  • Page 21: Protecting A Fax Machine Or Modem

    The Emergency Power OFF feature functions when the Emergency Power OFF relay connector is plugged into the outlet on the back of the unit. INTegral Line-Interactive Uninterruptible Power Supply Unit—2kVA-T Power Innovations...
  • Page 22: Storing The System

    If the UPS will be stored for long periods of time, the battery must be charged once for every 90 days of storage. Keep the unit clean by dusting it with a dry cloth. Power Innovations INTegral Line-Interactive Uninterruptible Power Supply—2kVA-T...
  • Page 23: Maintenance

    ELECTRICAL WARNING This unit should not be serviced except by authorized individuals. Opening the case could cause accidental injury or death. Follow the troubleshooting guide below. If troubleshooting does not fix the problem, call Power Innovations. 5.2.1—Utility Power Functioning Scenario Possible Cause AC utility power is normal.
  • Page 24: 2-Utility Power Failing

    Save data or every second. disconnect loads soon. AC utility power fails. UPS has Battery has run out. UPS will restart when AC utility shut down automatically. power is restored. Power Innovations INTegral Line-Interactive Uninterruptible Power Supply—2kVA-T...
  • Page 25 0–40°C; 32–104°F Relative Humidity 0–95% non-condensing Audible Noise Less than 55dBA (at 1m) Physical (WxHxD) mm 145*215*431 Net Weight (kgs) 22.5 NEMA Outlets (100/110/115/120 VAC) Safety Safety Standard EN62040-1-1 Conformance EN62040-2 Marks INTegral Line-Interactive Uninterruptible Power Supply Unit—2kVA-T Power Innovations...
  • Page 26 This page intentionally left blank.
  • Page 27: No Battery Maintenance

    7—Battery Information 7.1—No Battery Maintenance No maintenance is necessary to operate the batteries. To get batteries serviced, call Power Innovations: Power Innovations International, Inc. Phone: 801-785-4123 Email: support@power-innovations.com ELECTRICAL WARNINGS This system contains batteries with a high short-circuit current. Even when disconnected from outlet power, UPS components are still connected to batteries.
  • Page 28 This page intentionally left blank.
  • Page 29: Limited Warranty

    The warranty includes twelve-month coverage on parts only. If any part or portion of the Power Innovations product fails to conform to the warranty within the warranty period, Power Innovations, at its option, will furnish new or rectory remanufactured products for repair or replacement of that portion or part.
  • Page 30: Warranty Claims

    Power Innovations Service Department for authorization and an RMA number. 8.3—Limitation of Remedies Power Innovations’ entire liability and the User’s exclusive remedy will be repair or replacement of the unit if all conditions described under 8.1—Limited Warranty have been met. 8.3.1—Indirect Damages...
  • Page 31 Company Information The INTegral Line-Interactive UPS System is distributed by Power Innovations International, Inc. If there are any questions or comments about this product, please call us: Power Innovations International, Inc. Phone: 801-785-4123 Fax: 801-785-6999 Email: support@power-innovations.com Web: www.power-innovations.com Product names mentioned herein may be trademarks and/or registered trademarks of their respective companies.