Sign In
Upload
Manuals
Brands
Siemens Manuals
Gateway
A53457
Siemens A53457 Manuals
Manuals and User Guides for Siemens A53457. We have
1
Siemens A53457 manual available for free PDF download: Installation & Maintenance
Siemens A53457 Installation & Maintenance (138 pages)
WAYSIDE ACCESS GATEWAY WAG
Brand:
Siemens
| Category:
Gateway
| Size: 2.6 MB
Table of Contents
Proprietary Information
2
Translations
2
Warranty Information
2
Sales and Service Locations
2
Document History
3
Notes, Cautions, and Warnings
11
Electrostatic Discharge (Esd) Precautions
12
Table of Contents
13
List of Figures
16
Glossary
19
1 Description
23
General
23
Figure 1-1. General Network Overview
24
Figure 1-2. Wayside Access Gateway
26
Table 1-1. WAG Ports
26
Pinouts for J1
27
Pinouts for J2
27
Table 1-2. Pinouts for J1
27
Table 1-3. Pinouts for J2
27
Echelon Interface (J4) Characteristics
28
Pinouts for J3A/J3B
28
Pinouts for J4
28
Table 1-4. Pinouts for J3A/J3B
28
Table 1-5. Pinouts for J4
28
LED Indicators
29
Product Specifications
29
Physical Specifications
29
Dimensions
29
Power Specifications
29
Environmental Specifications
29
Default Factory Settings
30
Figure 1-3. Persistent Serial Tunneling
31
Persistent Serial Tunneling (Pst) Functionality
31
Figure 1-4. Office Systems Interface
32
Office System Interface (Osi) Functionality
32
Boot Loader Rs485 J1/J2 Jumper Detection
34
Figure 1-5. J1/J2 Jumper Auto Detect Option
34
External J1/J2 Jumpers
35
1.10 Rs485 Operation
36
Figure 1-6. RS485 Operational Interconnection
36
J1/J2 Jumper Detect Test Frames
36
Figure 1-7. RS485 Cable Interconnections
37
Figure 1-8. RS485 Cable Interconnections
37
1.11 Hdlc-Ui Operation
38
Wag Message Management
24
Wag Hardware Interface
26
Ports
26
2 Installation and CONFIGURATION
39
Pre-Startup
39
Hardware Installation
39
Hardware Mounting
39
Wiring
39
Equipment Connection to Wag
40
Connecting to Safetran Ethernet Radio A53325
40
Figure 2-1. Safetran Ethernet Radio A53325
40
Connecting to an Ethernet Hub
41
Figure 2-2. Ethernet Hub
41
Connecting to an Ethernet Hub and Safetran Ethernet Radio A53325
42
Figure 2-3. Ethernet Hub and Safetran Ethernet Radio A53325
42
Connecting Two Sites Using Modems
43
Figure 2-4. Connecting Two Sites Using Modems
43
Connecting Using Terminal Emulation Software
44
Figure 2-5. WAG Terminal Emulation Boot Screen
44
Table 2-1. PC Serial Port Settings
44
Figure 2-6. WAG Terminal Emulation Boot with Number 7 Screen
45
Figure 2-7. WAG Terminal Ready Screen
46
Figure 2-8. Hyperterminal Configuration Screen
46
Connecting Using Telnet
47
Figure 2-9. First Configuration Menu
47
Figure 2-10. Second Configuration Menu
48
Figure 2-11. Third Configuration Menu
48
Configuration of the Wag
49
Type 7 ATCS Address
49
Figure 2-12. Type 7 ATCS Address Configuration Screen
49
Type 3 ATCS Address
50
Serial Port Interface
51
Figure 2-13. Type 3 ATCS Address Screen
51
Serial Format
52
Figure 2-14. Serial Port Interface Screen
52
Figure 2-15. Serial Format Screen
53
Figure 2-16. an Example of HDLC Tunneling
54
Figure 2-17. an Example of HDLC Tunneling Cable Interconnections
54
WAG Test Mode
55
Echelon Address
55
Figure 2-18. Echelon Configuration Screen
55
UDP Port Assignments
56
Figure 2-19. UDP Port Assignment Screen
56
Router Expiration Timer
57
Broadcast Medium
57
Figure 2-20. Router Expiry Timer Screen
57
TCP Port Assignments
58
Figure 2-21. Broadcast Interface Screen
58
DHCP Server
59
Figure 2-22. TCP Configuration Screen
59
Figure 2-23. DHCP Server Screen
59
WAG IP Address
60
Figure 2-24. Change WAG IP Address Screen
60
Type 7 Address Route Length
61
Figure 2-25. Type 7 Address Route Length Screen
61
IP Network Mask
62
Radio Site ID Bindings
62
Figure 2-26. Change IP Network Mask Screen
62
Figure 2-27. Radio Site Ids/Dhcp Bindings Screen
63
Figure 2-28. DHCP Binding Screen
63
Figure 2-29. Change Binding IP Address Screen
64
Figure 2-30. Change Binding IP Address Bytes 1 through 4 Screen
64
Figure 2-31. Change Binding Left Transmit Channel Screen
64
Figure 2-32. Change Binding Left Transmit Power Screen
64
Figure 2-33. Change Binding Left Transmit Speed Screen
65
Figure 2-34. Change Binding Left Receive Channel Screen
65
Figure 2-35. Change Binding Right Transmit Channel Scree
65
Figure 2-36. Change Binding Right Transmit Power Screen
66
Figure 2-37. Change Binding Right Transmit Speed Screen
66
Figure 2-38. Change Binding Right Receive Channel Screen
67
Figure 2-39. Radio Site Ids/Dhcp Bindings Screen - after Binding Configuration
67
Figure 2-40. Selected Binding Screen - after Binding Configuration
68
If more than One Radio Is Co-Located with a DHCP Serving WAG
68
DHCP Client
69
2.6.17 WAG Circuit ID
70
Figure 2-41. DHCP Client
70
Figure 2-42. Change WAG Routing Region Screen - Initial Screen
70
Figure 2-43. Change WAG Routing Region Screen - after Digits Entered in First Field
71
Figure 2-44. Change WAG Routing Region Screen - after Digits Entered in Second Field
71
Figure 2-45. Change Routing Region Domain One - Initial Screen
72
Figure 2-46. Change Routing Region Domain One - IP Address Screen
73
Figure 2-47. Change Routing Region Domain One - Symbolic Name Screen
73
ATCS Server UDP Port Number
74
Telnet Port Numbers
74
Figure 2-48. Change ATCS Server UDP Port Number Screen
74
Figure 2-49. Change Telnet Port Numbers Screen
75
Figure 2-50. Change WAG Telnet Port Number Screen
75
Figure 2-51. Change Serial Telnet Port Number Screen
75
Genisys Wait Poll Response
76
ATCS Retry Wait
76
Figure 2-52. Change Genisys Poll Response Wait Timer Screen
76
ATCS Max Retries
77
Figure 2-53. Change ATCS Retry Timeout Scree
77
Figure 2-54. Change ATCS Retry Timeout Screen
77
Genisys Poll Starting Station
78
Genisys Poll Ending Station
78
Figure 2-55. Change Genisys Starting Station Polling Number Screen
78
Fragile Telnet Connection
79
Figure 2-56. Change Genisys Ending Station Polling Number Screen
79
Figure 2-57. Select the New Fragile Telnet Connections Option Screen
79
Persistent Serial Tunnel
80
Figure 2-58. Change Persistent Serial Telnet IP Address Screen
80
Figure 2-59. Change Persistent Serial Telnet IP Address Screen
81
Figure 2-60. Change Persistent Serial Telnet IP Address Symbolic Name Screen
81
Typical PST Configuration Parameter Settings
81
Primary and Secondary DNS
82
Table 2-2. Typical WAG Configuration Settings for PST Function
82
Figure 2-61. Change Primary DNS IP Address Screen
83
Default IP Gateway
84
Figure 2-62. Change Secondary DNS IP Address Screen
84
Figure 2-63. Change Default Gateway IP Address Screen
85
WAG Site ID
86
Route RAW Echelon: no
86
Figure 2-64. Change WAG Site Name Screen
86
Route Unknown Outbound Echelon: no
87
Figure 2-65. RAW Echelon Message Option
87
Telnet Password: Disabled
88
RS485 J1/J2 Jumper Detect: Enabled
88
Figure 2-66. Unknown Outbound Echelon Message Option
88
Figure 2-67. Telnet Password Option
88
3 Operation
89
Introduction
89
Table 3-1. WAG Commands
89
Viewing the Status
90
Additional Status Information When WAG Configured for OSI
91
Genisys Status Report
92
Viewing the Routing Table
92
Viewing Mac Addresses
93
Viewing the Wag Configuration
93
Persistent Serial Tunnel Command
94
Changing the Diagnostic Verbosity Levels
95
Send Wink Request to a Wag
95
Sending a Ping to an Ip Address
96
3.10 Sending a Route Ping Request
96
3.11 Tracing an Interface
97
3.12 Setting the Current Date
102
3.13 Setting the Current Time
102
3.14 Uploading/Downloading Files
102
3.15 Data/Command Mode from a Serial Interface
103
Returning the Serial Interface to Command Mode from Atelnet Session
103
3.17 Restarting the Wag
103
3.18 Viewing Software Information
104
3.19 Reviewing the Logs
104
3.20 Log Entries
106
Table 3-2. Log Entry Descriptions
107
3.21 Clearing the Log
115
3.22 Reqip
116
3.23 Wagreport
116
3.24 Ttime
117
3.25 Revisions
118
4 Troubleshooting
119
Introduction
119
Devices Not Talking to each Other on Network
119
Entries Not in Routing Table
119
Wag Lights Are off
122
Wag will Not Complete the Boot Process
122
Boot Menu Does Not Appear
123
Cannot Telnet to Wag
124
MULTIPLE Wags HAVE same IP ADDRESS
124
5 0 Maintenance
127
Introduction
127
Downloading Software to Wag Using Xfiles Command
127
Figure 5-1. ZMODEM File Transfer Menu
127
Uploading Software from Wag Using Xfiles Command
128
Figure 5-2. Send File Pop-Up Window
128
Figure 5-3. Zmodem File Send Screen
128
Figure 5-4. ZMODEM File Transfer Menu
129
Figure 5-5. Receive File Pop-Up Window
129
Upgrading Wag Via Boot Options Screen
130
Figure 5-6. Zmodem File Receive Screen
130
Figure 5-7. WAG Boot Screen
130
6 Using Advanced Options
131
Introduction
131
Boot Menu Options
131
Figure 6-1. Boot Options Screen
131
Table 6-1. List of Boot Options
131
Debugging from the Boot Menu
132
Figure 6-2. Boot Options Screen
132
Figure 6-3. Debugger Commands List
132
Available Commands and Description
133
Upgrading the Xilinx Code
135
Figure 6-4. Exception Test Diagnostic Information
135
Troubleshooting Commands
136
Using TESTMODE
136
Using XDUMP
137
Figure 6-5. Xdump Block Display
137
Figure 6-6. Xdump Partial Block Display
137
Advertisement
Advertisement
Related Products
Siemens Advance Network Gateway
SIEMENS A53
Siemens A53689
Siemens A53685
Siemens A53687
Siemens A50
SIEMENS A51
Siemens A56
Siemens A5Q00004117
Siemens Gigaset A590
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL