CDX-L300/L460X
EXTENSION CABLE AND SERVICE POSITION
When repairing or servicing this set, connect the jig (extension cable)
as shown below.
MG-393X-121//K
• Connect the MAIN board (CNP701) and the SERVO board (CN1)
with the extension cable (Part No. J-2502-011-1).
MG-393XA-121//K
• Connect the MAIN board (CNP701) and the SERVO board (CN1)
with the extension cable (Part No. J-2502-062-1).
4
MAIN BOARD CNP701
J-2502-011-1
MAIN BOARD CNP701
J-2502-062-1
SERVO BOARD CN1
SERVO BOARD CN1