Adf Related Service Call; Laser Optical Unit Related Service Call - Toshiba e-STUDIO203 Service Handbook

Hide thumbs Also See for e-STUDIO203:
Table of Contents

Advertisement

5.1.8

ADF related service call

No service call for the ADF (MR-2017).
5.1.9

Laser optical unit related service call

[CA1]
Polygonal motor is abnormal
Is the polygonal motor rotating?
NO Æ
l
l
l
l
l
l
l
l
È
YES
1) Check if the conductor pattern on the MAIN board is short circuited or open circuited.
2) Replace the MAIN board.
[CA2]
H-Sync detection error
Are the harness open circuited and the connectors disconnected or misconnected between
the MAIN board (CN21, CN22) and laser optical unit?
YES Æ 1) Connect the disconnected connectors.
È
NO
1) Replace the MAIN board.
2) Replace the laser optical unit.
December 2005 © TOSHIBA TEC
1) Check if the connector of the harness is disconnected between MAIN
board (CN24) and the laser optical unit.
2) Check if the harness is open circuited and the connector pin is dis-
connected.
3) Check if the conductor pattern on the MAIN board is short circuited or
open circuited.
4) Replace the laser optical unit.
5) Replace the MAIN board.
2) Replace the laser optical unit if the harness is open circuited.
5 - 17
06/07
e-STUDIO163/203 TROUBLESHOOTING
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio163

Table of Contents