Installation instructions
Fig. 8
Concentric kit part # ESHCK
Fig. 9
Concentric kit vent assembly
3" stainless steel pipe
Fig. 10 Concentric kit installation
3.3.2
Venting Specifications
Install appliance as close to point of vent termination as
possible. The exhaust piping must vent directly to the
outside of the structure.
Horizontal sections of vent must pitch upward towards
termination ¼" for every foot of horizontal length, to
prevent the pooling of condensate, and be supported at
4 foot intervals with overhead hangers.
Exception: horizontal run between last elbow and
termination must pitch down to termination 1/4" per
foot. Note: For horizontal terminations, venting must
terminate once it penetrates to the outside of the
10
structure. There must be no sections of vent pipe
exposed to the outdoors other than the termination.
Note: Listed thimbles or collars are necessary where
venting passes through wall and ceiling partitions. If the
vent system passes through combustible areas where
the vent clearance requirements cannot be maintained,
it is permissible to chase straight sections of sealed 3
inch single wall vent through 4 inch (or greater) Type-B
vent. The distance to combustibles using this chase
technique is 1 inch. Note: Type-B vent must never be
6720608782-09.1Av
used as the actual exhaust vent system for the
appliance, as it is not gas tight and illegal for use with
this appliance. This will create a serious health hazard
and void the warranty.
VENTING
90° elbow
Terminal
6720608782-10.1Av
Horizontal
Terminal
3" horiz.
terminal
with damper
12"
3" Vertical
Terminal
Table 3 3" Terminator Part Numbers
VENTING
90° elbow
Terminal
Horizontal
Terminal
4" horiz.
6720608782-11.1Av
terminal
with damper
4"
terminal
Table 4 4" Terminator Part Numbers
For specific questions concerning vent material, speci-
fications, usage or installation, please contact the vent
manufacturer directly.
3"
Z flex
3"
2SVEEWCF0390
3" Tee
2SVSTTF03
3"
2SVSTB03
2SVSHTD03
2SVSRCF03
4"
Z flex
4"
2SVEEWCF0490
4" Tee
2SVSTTF04
4"
2SVSTB04
2SVSHTD04
vertical
2SVSRCF04
Protech
Heat Fab
FSELB9003
9314
FSTT3
9390TEE
FSTB3
N/A
N/A
N/A
FSRC3
5300CI
Protech
Heat Fab
FSELB9004
9414
FSTT4
9490TEE
FSTB4
N/A
FSRC4
5400CI
N/A
N/A