System Configuration
Cluster Setting Defaults
TIP:
TIP:
3-106
b. Test successful message (final screen) – Enter the text for the final, test
successful window. ProCurve recommends that this text informs the
end-user that the test was successful and provides any additional
helpful information such as instructions, notices, and so on.
Footer (most screens) – Enter the text for the footer that appears on
c.
most of the end-user windows. ProCurve recommends that this text
includes a way to contact you if they need further assistance. You can
format the text in this field with HTML characters.
Click ok.
2.
Specifying the End-user Test Failed Pop-up Window
To specify the end-user test failed pop-up window:
NAC 800 Home window>>System configuration>>End-user screens
1.
Select the Pop up an end-user notification when an endpoint fails one or
more tests check box to turn the pop-up window on (clear the check box
to turn it off).
2.
Enter the customization information:
a.
Notification pop-up URL – In the Notification pop-up URL text box, the
default is:
https://ServerIpaddress:89
This URL points to port 89 on the NAC 800 ES (the default end-user
screen that shows the test failed results), and is where the user is
directed to when they click the Get details button on the new pop-up
window.
Enter a different URL if you have a custom window you want the users to see.
For example, you might have a location that provides links to patch or
upgrade their software.
b. Test failed pop-up message – In the Test failed pop-up message text box,
enter the message the end-user views on the standard pop-up window.
You can verify your changes to the end-user access screens immediately by
pointing a browser window to port 88 of your NAC 800 installation. For
example, if the IP address of your NAC 800 installation is 10.0.16.18, point the