Gas dryer completely inoperative.
Note: Always check wiring to the components.
Note: If a fault code is displayed, the dryer will not operate.
Measure the voltage drop
between pins 1 & 2 of the
eight pin plug of the wire
harness to the control
0.
Defective household
power supply or
broken wire between
dryer terminal block
and thermal limiter.
Dryer completely
inoperative.
Does the control beep or
the LED flash when the
start button is pushed.?
No.
board.
120VAC.
Defective control
board.
Measure the voltage drop
between pins 1 & 2 of J-4
120VAC.
Defective control
board.
>120VAC - 0<
Check the resistance of the
control thermistor at room
50,000 Ohms +/- 10%.
Defective
electronic
control.
57
Yes.
Is an error
code display.
Yes.
Refer to error
No.
code chart.
0.
Defective door
switch.
temperature.
More or less
than 50,000
Ohms +/- 10%.
Defective
thermistor.