EN | 2 LTC 2600 Series | Instruction Manual | Important Safeguards Important Safeguards 1. Read, Follow, and Retain Instructions - All safety 10. Power Sources - Operate the unit only from the type and operating instructions should be read and of power source indicated on the label.
EN | 3 LTC 2600 Series | Instruction Manual | Safety Precautions Safety Precautions For Indoor Product 1. Water and Moisture - Do not use this unit near water - for example, in a wet basement, in an unprotected outdoor installation, or in any area classified as a wet location.
EN | 4 LTC 2600 Series | Instruction Manual | FCC & ICES Information FCC & ICES INFORMATION Sicherheitshinweise (U.S.A. and Canadian Models Only) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:...
Page 5
EN | 5 LTC 2600 Series | Instruction Manual | Safety Precautions Medidas de Segurança Veiligheidsmaatregelen CUIDADO: PARA REDUZIR O RISCO DE CHOQUE VOORZICHTIG: OPEN DE BEHUIZING OF DE ACHTERKANT ELÉCTRICO, NÃO RETIRE A TAMPA (OU A PARTE VAN HET APPARAAT NIET. ZO VERMINDERT U HET RISICO POSTERIOR).
EN | 7 LTC 2600 Series | Instruction Manual | Introduction INTRODUCTION SERVICE Command Console Language If the unit ever needs repair service, the customer should (CCL) contact the nearest Bosch Security Systems, Inc. Service Center for return authorization and shipping instructions.
Using the DEFAULT command will command line. cause the loss of all previously entered user settings. Prefix combinations used in the LTC 2600 Series CCL When a CCL command is received that contains an error include MS and MR (examples provided here for in its format or parameter values, a descriptive message reference).
EN | 9 LTC 2600 Series | Instruction Manual | Introduction NOTE: Some MS commands require that a 16-position MR-VCR-ENCODE-LIST: 1 2 10 11 12 16 5 (bit) table be entered as the value of the parameter that Returned camera numbers in the VCR encode list.
EN | 11 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands MS-ACTION-CLEAR <camera map> 4.2 Detailed Descriptions of MS This command clears the action status of the Commands multiplexer. For each bit which is 1 <camera map>, MS-ACTION-ALARM-RELAY <responds to>...
Page 12
EN | 12 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands MS-ACTION-SENSITIVITY <camera#> <level> Monitor Zone Groups This command sets the action detector sensitivity for each specified camera to a certain level. 1 2 3 4 Parameter values for <camera# > and <level > are as...
Page 13
EN | 13 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands MS-ALARM-BEEPER <boolean> MS-ALARM-HISTORY <camera map> This command enables or disables the beeper when an This command clears the alarm status history for alarm condition is present.
Page 14
EN | 14 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands MS-AUTOSET <boolean> <boolean> <boolean> MS-CAM-FULL <monitor> <camera#> <boolean> <boolean This command assigns the specified camera to the This command carries out the autoset function for the specified monitor if the monitor is in full screen mode.
Page 15
EN | 15 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands MS-CAM-VIDEOLOSS-MESS <table 16> MS-FREEZE <monitor> <cameo#> <boolean> This command enables or disables video loss messages. This command enables or disables the freeze function for the specified cameo on the specified monitor.
Page 16
EN | 16 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands MS-LOG-SETUP <boolean> <boolean> <boolean> SCREEN MODES AND SCREEN SEGMENT <boolean> <boolean> NUMBERING The numbers shown inside the cameos indicate the This command enables of disables logging of the...
Page 17
EN | 17 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands mode = 0 This command specifies the text brightness and Full Screen Mode background outline brightness (whether large or small) for Parameter values for <text-bright> and <background-bright>...
Page 18
EN | 18 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands MS-MON-TIME-ENABLE <monitor> <boolean> MS-OPERATION-SIMPLEX <mode> This command enables or disables time/date display This command sets the operating mode for simplex for the specified monitor. multiplexer models.
Page 19
EN | 19 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands Parameter values for <password> are MS-SEQ-ENABLE <monitor> <boolean> <digit><digit><digit><digit> where <digit> equals This command enables or disables sequencing for the any number between 0 and 9.
Page 20
EN | 20 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands MS-SEQ-MON-A <seq-mode> <camera list> MS-STATUS <camera map> <camera map> <camera This command defines the sequencing mode (i.e. map> camera-to-cameo assignment) for monitor A. This command is used to clear the videoloss, alarm, and action status conditions of the multiplexer (in that Parameter values for <seq-mode>...
Page 21
EN | 21 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands If the settings were never saved or if the DEFAULT Parameter values are defined as follows: command is used, the Save memory locations will <item> 1 to 64 (time-event reference #) contain the default system settings.
Page 22
EN | 22 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands <SMTSTFS> 1 to 127 per table 8 format below: Macro commands can also be created by combining more than one CCL command in the CCL command...
Page 23
EN | 23 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands MS-TIME-EVENT-STATUS <start-item> <end-item> MS-VCR-ALARM-RECORD <vcr> <record mode> <status> This command sets the VCR response to an alarm. This command allows you to enable or disable Parameter values for <vcr> and <record mode> are as individual time-events.
Page 24
EN | 24 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands MS-VCR-MODEL <vcr> <vcr-model#> MS-VCR-PLAYBACK-ALGORITHM <algorithm> This command defines the VCR attached to the <vcr> This command sets the teletext algorithm for playback parameter to be the type corresponding to the <vcr- for all VCRs.
Page 25
EN | 25 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands MS-VCR-RELAY <vcr> <responds to> <polarity> Parameter values are as follows: This command sets the response and polarity for the <custom-vcr-model#> 1 to 6 (corresponding to relay connected to the VCR attached to the specified custom VCR setting 1 to 6) monitor.
Page 26
EN | 26 LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands MS-WINTER-TIME <date> This command sets the date when the time-of-day clock will be put back by one hour (from Daylight Saving Time back to Standard Time). At 2:00 a.m. / 02:00 on the date set, the hour is put back to 1:00 a.m.
EN | 28 LTC 2600 Series | Instruction Manual | Multiplexer Read (MR) Commands MR-ACTION-HISTORY 4.2 Detailed Descriptions of MR This command returns the action status history for Commands cameras in the <camera map>. MR-ACTION-ALARM-RELAY NOTE: The <camera map> consists of a 16-bit map NOTE: This command returns the settings for Relay 1 with a bit for each camera in the multiplexer.
Page 29
EN | 29 LTC 2600 Series | Instruction Manual | Multiplexer Read (MR) Commands MR-ACTION-ZONES <camera#> <map row#> MR-ALARM-ENABLE This command returns the action zone map for the This command returns the values of enabled specified map row and camera number.
Page 30
EN | 30 LTC 2600 Series | Instruction Manual | Multiplexer Read (MR) Commands MR-CAM-AUTOCOLOR MR-CAM-VIDEOLOSS-MESS <table 16> This command returns the setting for the multiplexer This command returns a 16-bit table value for the autocolor operation. videoloss message status of individual cameras.
Page 31
EN | 31 LTC 2600 Series | Instruction Manual | Multiplexer Read (MR) Commands MR-HELP MR-MON-A-DISPLAY <mode> This command displays a screen of help instructions This command returns the camera list being displayed regarding MR command entry. in the specified mode on Monitor A.
Page 32
EN | 32 LTC 2600 Series | Instruction Manual | Multiplexer Read (MR) Commands MR-MON-TEXT MR-MON-TIME-POSITION This command returns the foreground and background This command returns the time/date display row brightness (respectively) for all text on all monitors. position for any enabled monitors and for both small and large text.
Page 33
EN | 33 LTC 2600 Series | Instruction Manual | Multiplexer Read (MR) Commands MR-OPERATION-DUPLEX MR-SEQ-ENABLE <monitor> This command returns the operating modes for duplex This command returns the setting (enabled/disabled multiplexer models. sequencing) for the specified monitor if its display mode is Full or Quad.
Page 34
EN | 34 LTC 2600 Series | Instruction Manual | Multiplexer Read (MR) Commands MR-SEQ-MON-A <seq-mode> MR-STATUS <camera map> <camera map> This command returns the camera list being sequenced <camera map> <camera map> <camera map> in the specified mode on monitor A.
Page 35
EN | 35 LTC 2600 Series | Instruction Manual | Multiplexer Read (MR) Commands MR-TIME-EVENT <start-item> <end-item> MR-TIME-EVENT-COMMAND <start-command#> This command returns the time-event parameters for a <end-command#> This command returns the command number and selected single time-event (if <start-item> and <end- CCL command for a selected single command (if start item>...
Page 36
EN | 36 LTC 2600 Series | Instruction Manual | Multiplexer Read (MR) Commands MR-VCR-ACTION-RECORD <vcr> MR-VCR-CUSTOM <custom-vcr-model#> <vcr- This command returns the action record mode for the mode> specified VCR. This command returns the parameters for the custom VCR definition specified by <custom-vcr-model#>...
Page 37
EN | 37 LTC 2600 Series | Instruction Manual | Multiplexer Read (MR) Commands MR-VCR-RECORD-LIST <vcr> MR-VCR-TITLE <vcr-model#> This command returns the record camera list for the This command returns the title of the VCR definition VCR attached to the specified output.
EN | 38 LTC 2600 Series | Instruction Manual | General Commands MR-VIDEOLOSS-OUT-ENABLE GENERAL COMMANDS This command returns the status (enabled/disabled) of Summary of General Commands the videoloss relay output. Command Function Description Parameter values are: ABBR <command> <text> Defines an abbreviation to be used instead of the command string in the ASCII protocol.
EN | 39 LTC 2600 Series | Instruction Manual | General Commands AUX-TGL <camera#> <auxiliary#> 6.2 Detailed Descriptions of General This command toggles the specified auxiliary Commands function/position on the specified receiver/driver ABBR <command> <text> (<camera#>). This command defines an abbreviation to be used instead of the command string in the ASCII protocol.
Page 40
EN | 40 LTC 2600 Series | Instruction Manual | General Commands PREPOS <logical cam#> <pre-position#> This command selects hexadecimal entry of numeric This command sends the specified camera to the values. In ASCII mode, this only affects input; output specified pre-position.
Page 41
EN | 41 LTC 2600 Series | Instruction Manual | General Commands R/C <logical cam#> <OpCode#> <data> This command sets the receiver/driver functions according to the parameters entered (refer to the following chart for a detailed explanation of parameter values and associated functions).
Page 42
EN | 42 LTC 2600 Series | Instruction Manual | General Commands EXAMPLE: To activate pre-position # 16 on camera # TIME 1, enter the following command: LTC 2600>R/C 1 2 15 This command displays the system time. NOTE: Since the decimal mode is being assumed, the...
EN | 43 LTC 2600 Series | Instruction Manual | Appendix A Function codes may be added together to operate Extended elements multiple functions with a single command line. Note CCL Grammar Parameter Definitions that the current AutoDome series lens only provides auxiliary#: 1..7...
Page 44
EN | 44 LTC 2600 Series | Instruction Manual | Appendix A CCL Grammar Parameter Definitions CCL Grammar Parameter Definitions <monitor> = 1 | 2 1 = Monitor A <revision> = <major revision> SPACE <minor revision> [SPACE E <engineering 2 = Monitor B revision>]...
EN | 45 LTC 2600 Series | Instruction Manual | Appendix B IMPORTANT NOTES (PERTAINING TO THE APPENDIX B: DETAILED USE OF CCL COMMANDS IN AND DURING COMMAND TIME-EVENTS): REFERENCE MATERIALS 1. CCL commands that affect the operating modes of...
Page 46
EN | 46 LTC 2600 Series | Instruction Manual | Appendix B SMTWTFS (SUNDAY THROUGH SATURDAY) Disabled: The user has disabled the event (either with This value selects which days of the week on which a the MS-TIME-EVENT or MS-TIME-EVENT-STATUS time event will execute.
Page 47
EN | 47 LTC 2600 Series | Instruction Manual | Bosch Security Systems | July 12, 2004...