Table of contents General Information .................... Information on protection of the environment ................Before using the appliance for the first time ..................Safety Instructions ....................Intended use ................................Technical safety ..............................Special information for gas cookers ......................Proper use ................................Correct installation .............................
General information NFORMATION ON PROTECTION OF THE EFORE USING THE APPLIANCE FOR THE FIRST ENVIRONMENT TIME NOTE: These operating instructions apply to Disposal of transport packaging several appliance models It is possible that Your new appliance was sent to you in individual features are described which do not protective packaging.
Safety instructions Intended use If the appliance is improperly installed, serviced or repaired, the user may be placed in This extractor hood complies with the considerable danger for which the stipulated safety regulations. Improper use manufacturer is not liable. may result in injury or damage. Changes to the electrical or mechanical The extractor hood may be used in the installation are dangerous and must not be...
Safety instructions Special information for gas cookers Safe operation is possible provided the low pressure in the installation room of the heating When installing the extractor hood above appliance does not exceed 4Pa (0.04mbar). gas hobs, observe the appropriate national This can be achieved if the combustion air can statutory regulations (e.g.
Safety instructions Proper use Correct installation Clean the extractor hood thoroughly before Check the manufacturer’s specifications for using for the first time. the cooker to determine whether an extractor hood can be operated over it. Before cleaning and servicing the extractor hood, isolate it from the power supply by If the manufacturer of the cooker has not pulling out the mains plug or switching off the...
Operating modes The extractor hood can be used in exhaust air and circulating air mode. Appliance dimensions Exhaust air Exhaust-air mode The air which is drawn in is cleaned by the grease filters and conveyed to the exterior by a pipe system.
Operation NOTE: It is recommended to switch on the The description of the operation applies to blower when you start cooking and not to several appliance models. It is possible that switch it off again until several minutes after you individual features are described which do not have finished cooking.
Cleaning and care Metal-mesh grease filters OOKING AFTER THE APPLIANCE The metal-mesh grease filters absorb the Suitable cleaning agents and care products grease particles from the kitchen fumes. for your appliance can be purchased via the Hotline or from the Online Shop (see cover The filter mats consist of fire-proof metal.
Removing and installing the grease filters Before removing and installing the grease Activated carbon filters bind the odours in filters, always follow the instructions and circulating-air mode. warnings in the chapter entitled ”Safety instructions”! Removing and installing the metal-mesh Installing and removing the activated grease filters carbon filters 1.
Changing the bulbs Changing the filament bulbs Before changing the bulbs, always follow the instructions and warnings in the chapter 1. Lift the bulb cover slightly. entitled ”Safety instructions”! 2. Push the bulb cover towards the middle of the appliance. The description of changing the bulbs applies to several appliance models.
Installation instructions Connecting pipes Prior to installation, always follow the instructions and warnings in the chapter The diameter of the exhaust air pipes entitled ”Safety instructions”! should not be less than 150 mm. Exhaust-air mode Round pipes: We recommend an inner diameter of The exhaust air is conveyed upwards via a 150 mm, however at least 120 mm.
Installation instructions If a permanent connection is required LECTRICAL CONNECTION A disconnector must be provided on the Before connecting the appliance to the installation side. Switches with a contact power supply, always follow the instructions opening of more than 3 mm and all-pole and warnings in the chapter entitled ”Safety disconnection are regarded as disconnectors.
Installation The extractor hood is designed to be Installation preparations mounted on the wall. 1. Mark a centre line on the wall from the ceiling to the lower edge of the extractor During installation, optional accessories may hood. also require fitting. 2.
Installation Attachment and alignment 1. Initially remove the protective foil from the back of the extractor hood and, following installation, remove foil completely. Mount the extractor hood, ensuring that the Ⓐ back is attached firmly to the brackets 3. Align the extractor hood horizontally by turning the brackets..
Installation Installing the flue ducts 4. Place flue ducts on the extractor hood, push the inner flue duct upwards and attach the RISK OF INJURY left and right sides to the fixing bracket. The insides of the flue ducts may have sharp edges.