Craftsman 919.184190 Owner's Manual
Craftsman 919.184190 Owner's Manual

Craftsman 919.184190 Owner's Manual

Oil lubricated, single stage, vertical stationary air compressor
Hide thumbs Also See for 919.184190:
Table of Contents

Advertisement

Available languages

Available languages

Owner's Manual
Oil Lubricated
Single Stage
Vertical Stationary

AIR COMPRESSOR

Model No.
919.184190
• Safety Guidelines
• Assembly
• Operation
• Maintenance
• Service and Adjustments
• Troubleshooting
• Repair Parts
• Español
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears, Roebuck and Co., Hoffman Estates, IL 60170 U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
D24917
Rev. 2
9/20/04

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Craftsman 919.184190

  • Page 1: Air Compressor

    • Service and Adjustments • Troubleshooting • Repair Parts • Español CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60170 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D24917 Rev. 2 9/20/04...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS WARRANTY ..........2 SPECIFICATION CHART .
  • Page 3: Safety Guidelines

    SPECIFICATION TABLE Model No. 919-184190 Max. Developed HP Bore 2.875" Stroke 2.0" Voltage-Single Phase Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity 60 gallons Approximate Cut-in Pressure Approximate Cut-out Pressure SCFM @ 40 psig 12.4 SCFM @ 90 psig 10.2 Refer to Glossary for abbreviations...
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It Always operate the compressor in a well...
  • Page 5 HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It Drain tank daily or after each use.
  • Page 6 HAZARD WARNING: Risk of Electrical Shock WHAT CAN HAPPEN HOW TO PREVENT IT Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used properly Never operate compressor with it may cause electric shock.
  • Page 7 HAZARD WARNING: RISK OF BURNS WHAT CAN HAPPEN HOW TO PREVENT IT Touching exposed metal such as the Never touch any exposed metal parts on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns.
  • Page 8 HAZARD RISK OF UNSAFE OPERATION WARNING: WHAT CAN HAPPEN HOW TO PREVENT IT Unsafe operation of your air compressor Review and understand all instructions and warnings in this manual. could lead to serious injury or death to Become familiar with the operation and you or others.
  • Page 9: Glossary

    GLOSSARY When the tank pressure drops to a Become familiar with these terms certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called “cut-in”...
  • Page 10: Assembly

    ASSEMBLY Tools Required for Assembly NOTE: Use an air compressor oil such as Sears item number 9-16426 1 - 9/16” socket or open end wrench or SAE-20 (API CG/CD) heavy duty 1 - electric drill motor oil. Under extreme winter conditions use SAE-10 weight oil.
  • Page 11: Installation

    INSTALLATION HOW TO SET UP YOUR Drill holes in the surface for the concrete anchors. Install UNIT concrete anchors. Air Compressor Location Line up holes in surface with • Locate the air compressor in a holes in air compressor feet. clean, dry, and well ventilated Place the (4) washers (supplied) area.
  • Page 12 The supply line should have the Circuit is equipped with a 15 same electrical characteristics amp circuit breaker or 15 amp (voltage, cycle, phase) as the time delay fuse. NOTE: If motor. Refer to the motor compressor is connected to a nameplate, on side of motor, for circuit protected by fuses, use this information.
  • Page 13: Air Distribution System

    • Install a flexible coupling • A separate regulator is between the air discharge outlet recommended to control the air and main air distribution line to pressure. Air pressure from the allow for vibration. air tank is usually too high for individual air driven tools.
  • Page 14: Operation

    OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Tank Pressure Gauge: The air tank Pressure pressure gauge indicates the reserve Switch...
  • Page 15 Check Valve: When the air Before First Start-up compressor is operating, the check Serious damage valve is “open”, allowing compressed may result if the air to enter the air tank. When the air following break-in instructions are compressor reaches “cut-out” not closely followed.
  • Page 16: How To Start

    After 20 minutes, close the globe How to Start valve.The air tank will fill to “cut- Turn the On/Auto/Off lever to out” pressure and the motor will “AUTO” and allow air tank stop. pressure to build. Motor will stop when air tank pressure Before Each Start-Up: reaches “cut-out”...
  • Page 17: Maintenance

    MAINTENANCE Customer Responsibilities Daily or Before Every Every Every Every after Yearly each each hours hours hours hours ● Check Safety Valve ● Drain Air Tank ● Check Oil ● Change Oil Listen for Unusual ● Noise and/or Vibration ● Check Air Filter ●...
  • Page 18 To Check Safety Valve Drain air tank to If the safety valve release air does not work pressure before removing the oil fill properly, over-pressurization may cap or oil drain plug. occur, causing air tank rupture or NOTE: Use air compressor oil such explosion and possible serious as SAE-20 (API CG/CD) heavy duty injury.
  • Page 19 Air Filter Inspection and Replacement Hot surfaces. Risk of burn. Compressor heads are exposed when filter cover is removed. Allow compressor to cool prior to If the difference is greater or less servicing. than 1/16" loosen the set screw A dirty air filter will not allow the holding the motor drive pulley to compressor to operate at full the shaft and adjust the pulley’s...
  • Page 20: Service And Adjustments

    SERVICE AND ADJUSTMENTS Unit cycles Using an adjustable wrench, automatically when loosen pressure relief tube nut at power is on. When performing air tank and pressure switch. adjustments or repair, you may be Carefully move pressure relief exposed to voltage sources, tube away from check valve.
  • Page 21 Motor This motor has a manual thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. To restart: Place the On/Auto/Off lever in the Off postion.
  • Page 22: Storage

    STORAGE Water will Before you store the air compressor, condense in the air make sure you do the following: tank. If not drained, water will Review the "Maintenance" corrode and weaken the air tank section on the preceding pages causing a risk of air tank rupture and perform scheduled and possible serious personal maintenance as necessary.
  • Page 23: Troubleshooting

    TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressd air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. CORRECTION CAUSE PROBLEM...
  • Page 24 CORRECTION CAUSE PROBLEM Operate safety valve manually Air leak from Possible defect in safety by pulling on ring. If valve still safety valve. valve. leaks, it should be replaced. Decrease amount of air usage. Prolonged excessive use of Compressor is air.
  • Page 25 CORRECTION CAUSE PROBLEM Let motor cool off and see Motor will not Motor overload protection run. Motor paragraph in the switch has tripped Service and Adjustment section. Motor will start automatically Tank pressure exceeds when tank pressure drops pressure switch “cut-in” below “cut-in”...
  • Page 26: Repair Parts

    CORRECTION CAUSE PROBLEM Knocking Noise. Possible defect in safety Operate safety valve manually valve. by pulling on ring. If valve still leaks, it should be replaced. Defective check valve. Remove and clean, or replace. Loose pulley Tighten pulley set screw, see Repair Parts section for torque specifications.
  • Page 27 CONTENIDO GARANTÍA ............32 CUADRO DE ESPECIFICACIONES .
  • Page 28: Cuadro De Especificaciones

    CUADRO DE ESPECIFICACIONES Modelo Nº 919-184190 Máx. HP desarrollado Diámetro interior 2.875” (73.02mm) Carrera 2” (50.8mm) Tensión monofásica 240V Circuito mínimo requerido Tipo de fusible Acción retardada Capacidad de aire en el tanque 60 Galones (227.1 litros) Presión de corte de entrada Presión de corte de salida SCFM a 40 psig 12.4 Calibre de libras...
  • Page 29 INSTRUCCIONES IMPORTANTES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES LA OPERACIÓN O EL MANTENIMIENTO INADECUADOS DE ESTE PRODUCTO PODRÍAN OCASIONAR SERIAS LESIONES Y DAÑOS A LA PROPIEDAD. LEA Y COMPRENDA TODAS ADVERTENCIAS INSTRUCCIONES FUNCIONAMIENTO ANTES DE UTILIZAR ESTE EQUIPO. PELIGRO ADVERTENCIA: RIESGO DE EXPLOSIÓN O INCENDIO ¿QUÉ...
  • Page 30 PELIGRO ADVERTENCIA: RIESGO DE EXPLOSIÓN TANQUE DE AIRE: LAS SIGUIENTES CONDICIONES PODRÍAN, CAUSAR EL DEBILITAMIENTO DEL TANQUE, Y DETERMINAR SU EXPLOSIÓN VIOLENTA, DAÑOS A LA PROPIEDAD O SERIAS LESIONES. ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? 1. Drenaje inadecuado del agua condensada Drene el tanque diariamente o después de en el tanque, siendo la causa del óxido cada uso.
  • Page 31 PELIGRO ADVERTENCIA: RIESGO DE DESCARGA ELÉCTRICA ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? Su compresor de aire está accionado por Jamás opere el compresor a la intemperie electricidad. Como cualquier otro dispositivo cuando está lloviendo o en condiciones de eléctrico impulsado eléctricamente, si no se lo humedad.
  • Page 32 PELIGRO ADVERTENCIA: RIESGO DE QUEMADURAS ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? Jamás toque partes de metal expuestas en el Tocar el metal expuesto tal como el cabezal compresor durante o inmediatamente después del compresor o los tubos de salida del escape, de la operación.
  • Page 33 PELIGRO ADVERTENCIA: RIESGO DE OPERACIÓN INSEGURA ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? La operacion insegura de su compresor de aire Revise y comprenda todas las instrucciones y podría ocasionarle serias lesiones o la muerte advertencias contenidas en este manual. a usted u otros. Familiarícese con los métodos de operación y control del compresor de aire.
  • Page 34: Glosario

    GLOSARIO Presión mínima de corte: Cuando el Familiarícese con los siguientes términos, motor está apagado, la presión del tanque antes de operar la unidad: de aire baja a medida que usted continúa CFM: (Cubic feet per minute) Pies cúbicos usando su accesorio. Cuando la presión por minuto.
  • Page 35: Ensamblado

    ENSAMBLADO No se deben usar Herramientas requeridas para el aceites de Ensamblado viscosidad múltiple como 10W30 en 1 - Llave de tubo 9/16" o llave mecánica ningún compresor de aire. Estos de boca abierta aceites dejan depósitos de carbono en componentes críticos, reduciendo el 1 - Taladro eléctrico rendimiento y la vida útil del compresor.
  • Page 36: Instalación

    INSTALACIÓN CÓMO PREPARAR LA UNIDAD Haga coincidir la alineación de los orificios de la superficie, con el de las Ubicación del compresor de aire patas del compresor de aire. Coloque las (4) arandelas • Instale el compresor de aire en una (suministradas) entre el piso y las zona limpia, seca y bien ventilada.
  • Page 37 Que la línea de suministro eléctrico El circuito cuenta con un disyuntor tenga idénticas características de 15 amperios o un fusible de eléctricas (voltaje, ciclos, fases) que acción retardada de 15 amperios. las del motor. Para obtener dicha NOTA: Si el compresor está información deberá...
  • Page 38 • Entierre la cañería por debajo de la • Instale un acoplamiento flexible, línea de congelamiento y evite entre la salida de descarga del aire y huecos en los que la condensación la línea principal de distribución del se pudiese acumular y congelar. mismo, para permitir vibraciones.
  • Page 39: Operación

    OPERACIÓN Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicación de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 40 Válvula reguladora: Cuando el Antes de poner en marcha por compresor de aire se encuentra primera vez funcionando, la válvula reguladora esta Si las siguientes "abierta", permitiendo la entrada del aire instrucciones no comprimido al tanque de aire. Cuando el fuesen seguidas estrictamente, podrán nivel de presión del tanque alcanza el ocurrir serios daños.Este procedimiento es...
  • Page 41 Antes de cada puesta en marcha Cómo poner en marcha Coloque el interruptor On/Auto/Off en la Mueva la palanca On/Auto/Off a la posición "OFF". posición "AUTO" y deje que se incremente la presión del tanque. El Cierre la válvula de asiento. motor se detendrá...
  • Page 42: Mantenimiento

    MANTENIMIENTO Responsabilidades del cliente Cada Cada Cada Cada Diariamente Antes de cada o luego de Anualmente horas horas horas horas cada uso ● Verifique la válvula de seguridad ● Drenaje del tanque ● Verifique el aceite ● Cambio de aceite Escuche por ruido ●...
  • Page 43 Cómo verificar la válvula de Aceite seguridad Drene el tanque fin de liberar la Si la válvula de presión de aire antes de extraer la tapa seguridad no para el relleno de aceite, o el tapón trabaja adecuadamente, ello podrá para drenaje del aceite.
  • Page 44 Filtro de Aire Inspección y reemplazo Superficies calientes. Riesgo de quemaduras. Las cabezas del com- presor están expuestas cuando se retira la cubierta del filtro. Deje enfriar al compresor antes de darle servicio. Un filtro de aire sucio no permitirá que el Si la diferencia es mayor o menor compresor opere a plena capacidad.
  • Page 45: Servicio Y Ajustes

    SERVICIO Y AJUSTES La unidad cicla Utilizando una llave regulable, afloje automáticamente la tuerca del tubo aliviador de en cuanto la energía eléctrica es presión en el tanque de aire y el conectada. Al efectuar el mantenimiento interruptor de presión. Retire o reparación, usted quedará...
  • Page 46 Motor Extraiga el frente protector de la correa desenganchando sus broches. Este motor tiene un protector manual de Inserte un destornillador de punta sobrecarga térmica. Si el motor se plana bajo cada broche y haga sobrecalienta por cualquier motivo, el palanca hasta quitar la defensa de la protector de sobrecarga apaga el motor.
  • Page 47: Almacenaje

    ALMACENAJE Antes de guardar su compresor de aire, El agua se asegúrese de hacer lo siguiente: condensa dentro del tanque de aire. Si no se drena, ella Revise la sección "Mantenimiento" corroerá debilitando las paredes del de las páginas precedentes y ejecute tanque de aire, originando un riesgo de el mantenimiento programado de ruptura de sus paredes, y posibles...
  • Page 48: Guía De Diagnóstico De Problemas

    GUÍA DE DIAGNÓSTICO DE PROBLEMAS El desarrollo de reparaciones puede exponer a sitios con corriente viva, partes en movimiento o fuentes de aire comprimido que podrían ocasionar lesiones personales. Antes de intentar reparación alguna, desenchufe el compresor de aire y purgue toda la presión de aire del tanque.
  • Page 49 PROBLEMA CAUSA CORRECCIÓN Opere manualmente la válvula de Pérdida de aire Posible defecto en la válvula seguridad, extrayéndola por su en la válvula de de seguridad. anillo. Si la válvula pierde, deberá seguridad. ser reemplazada. El compresor no Excesivo y prolongado uso del Disminuya la cantidad de uso de esta aire.
  • Page 50 PROBLEMA CAUSA CORRECCIÓN Deje enfriar el motor y ver “motor” El motor no El interruptor de protección de en la sección Servicio y Ajustes funciona. sobre carga del motor se ha abierto. El motor arrancará automáticamente La presión del tanque excede cuando la presión del tanque caiga la presión de "corte máximo"...
  • Page 51: Lista De Partes

    PROBLEMA CAUSA CORRECCIÓN Golpeteo Posible defecto en la válvula Opere la válvula de seguridad de seguridad. manualmente tirando de su anillo. Si la válvula aun pierde, deberá ser reemplazada. Posible defecto en la válvula Extraiga y limpie o reemplace. de seguridad. Ajuste el tornillo de la polea;...
  • Page 52 NOTES/NOTAS 57- SP D24917...
  • Page 53 NOTES/NOTAS 58- SP D24917...
  • Page 54 NOTES/NOTAS 59- SP D24917...
  • Page 55 Get it fixed, at your home or ours! Your Home For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself.