38
en | Configuration
5.6.4
Alarm I/O submenu
Item
Input
Input action
Output
Output action
EXIT
AM18-Q0644 | v1.0 | 2013.03
Selection
None, high,
low
None,
Mode 1 to 6,
Night mode
Normally
open,
Normally
closed
VMD,
Ext. device,
Night mode,
Filter toggle
Installation Manual
Description
Select none to disable the alarm input.
Select active-high or active-low for the
alarm input connector.
Selects the operating mode of the
camera when the alarm input is active.
Selects the relay output mode.
VMD: - output relay closes on VMD
alarms.
External device: - make the output
relay available to remote
communication devices.
Night mode: - output relay closes when
camera is in monochrome mode.
Filter toggle: - output relay closes just
before the IR filter starts moving and
opens when video level has stabilized
(2 to 3 seconds)
Returns to Install menu.
DINION 5000 AN
Bosch Security Systems