Drive Tray Specifications; Power Supply Specifications; Cooling Module Specifications; Raid Management - Bosch DVA-12T Installation Manual

Iscsi premium series raid subsystem
Hide thumbs Also See for DVA-12T:
Table of Contents

Advertisement

RAID Subsystem DVA-12T | Installation Manual
7.3

Drive Tray Specifications

Height
Width
Depth
Key Lock
7.4

Power Supply Specifications

Nominal Power
DC Output
Input Frequency
AC Input
Power Factor Correc-
tion
Hold-up Time
Over-temperature
Protection
Cooling Fans
7.5

Cooling Module Specifications

Speed
Max. Air Flow (each
module)
Input Power
Rated Voltage
Temperature
7.6

RAID Management

Configuration
Performance Monitoring Yes
Remote Control and
Monitoring
Bosch Security Systems
Specification
28mm
110mm
218.92mm
Yes
Specification
350W
12.0V: 25A
5.0V: 25A
3.3V: 20A
47 to 63Hz
115VAC @ 6A or 240VAC @ 3A with PFC
Yes
At least 16ms at 115/230VAC full load after a loss of AC input
Auto shutdown when lost cooling or exceeded ambient tempera-
ture; over-voltage protection is also available.
Two fans for each unit (inside PSU)
Specification
High or low rotation speed controlled by firmware
High speed: 31.8 CFM
Low speed: 20.1 CFM
9/3.12W max.
DC 12V
Operating: -10 to +60ºC
Storage: -20 to +70ºC
Specification
Text-based firmware-embedded utility over RS-232C
through the included audio jack-to-DB-9 serial cable
The RAIDWatch Manager program using Ethernet
connection
Yes
Specifications | en
45
F.01U.027.798 | V1 | 2006.06