4.3.3
Applicable
model
NC
NP
(*1) See Figure 4.22.
(1)
(2)
(3)
C141-E270
Downloaded from
www.Manualslib.com
Cable connector requirements
Table 4.2 lists the recommended components cable connection.
Table 4.2 Recommended components for connection
Type
SCSI connector
Connector
(CN1)
Cable socket
(closed-end type)
SCSI cable (CN1)
Signal cable
Cable socket housing 1-480424-0
Power supply
cable (CN1)
Contact
Cable
Cable socket housing A3B-12D-2C
External operator
panel (CN1)
Contact
Cable
Cable socket housing FCN-723J024/2M
External operator
panel (CN2)
Contact
Cable
SCSI cable
Refer to Section 1.3 "Physical Requirements" and Section 1.4 "Electrical Requirements" of the
SCSI Physical Interface Specifications.
Power cable
HDDs must be star-connected to the DC power supply (one to one connection) to reduce the
influence of load variations.
DC ground
The DC ground cable must always be connected to the HDD because no fasten tab dedicated to SG is
provided with the HDD. Therefore, when SG and FG are connected in the system, it is necessary to
connect SG and FG at the power supply or to connect SG of the power supply to FG of the system.
manuals search engine
Part number
Name
(Size)
787311-4
71743-1085
DHJ-PAC68-2AN-
FG
5786090-7
UL20528-FRX-
68-P0.635
170148-1
(AWG18 to 24)
A3B-2630SCC
(AWG26 to 36)
FCN-723J-G/AM
(AWG28)
Reference
Manufacturer
(*1)
Tyco Electronics
AMP
Molex
Fujikura
Tyco Electronics
S1
AMP
Fujikura
Tyco Electronics
AMP
S2
Tyco Electronics
AMP
HIROSE
ELECTRIC
S3
HIROSE
ELECTRIC
FUJITSU
TAKAMIZAWA
FUJITSU
S4
TAKAMIZAWA
67