Removing The Gbic - HP LC2000r - NetServer - 128 MB RAM Manual

Fibre channel host bus adapter
Hide thumbs Also See for LC2000r - NetServer - 128 MB RAM:
Table of Contents

Advertisement

Figure 2-4. Copper Cable Connector

Removing the GBIC

To remove the GBIC, follow these steps:
1. Remove the Fibre Channel cable.
(a) If you are using the HSSDC Copper Cable, squeeze the tab to
remove. (See Figure 2-6. on page 10.)
2. (a) If you are using an optical GBIC, flip the bar of the GBIC to the
"OPEN" position and pull to remove. (See Figure 2-5. on page 10.)
(b) If you are using the HSSDC Copper GBIC, squeeze the tabs on both
sides of the GBIC. (See Figure 2-6. on page 10.)
3. Pull the module out of the receptacle.
4. For optical GBICs, reinsert the dust plug.
9