Power Supply Cord
Direct Wire
Fire Hazard
Use a new UL misted 30 amp power supply cord.
Use a UL misted strain relief,
Disconnect
power before making emectrica_ connections,
Connect neutram wire (white or center wire) to center
terminaa (silve0,
Ground wire (green or bare wire) must be connected
to
green ground connector,
Connect remaining
2 suppmy wires to remaining
2 terminals
(goBd).
SecureBy tighten
aH emectricat connections,
FaiBure to do so can resumt in death, fire, or
electrical
shock,
Fire Hazard
Use 10 gauge somid copper wire,
Use a UL misted strain
relief,
Disconnect
power before making emectricai connections.
Connect neutral wire (white or center wire) to center
terminal
(simve0.
Ground wire (green or bare wire) must be connected
to
green ground connector,
Connect remaining
2 suppmy wires to remaining
2 terminals
(gored).
Securety tighten
aH emectdcal connections.
Failure to do so can resumt in death, fire, or
emectrical shock.
1. Disconnect
power,
2. Remove the hold-down screw and terminal block cover.
......................................................
A
3.
A. Neutral ground wire
B. External ground conductor screw
C. Center, silver-colored
terminal block screw
D. Terminal block cover and hold-down
screw
Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a 3/4"(1.9 cm) UL listed strain
relief (UL marking on strain relief). Put the tabs of the two
clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is
pointing down, and hold in place. Tighten strain relief
screws just enough to hold the two clamp sections
together.
A. Strain relief tab pointing
up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing
down
Put power supply cord through the strain relief. Be sure
that the wire insulation on the power supply cord is inside
the strain relief, The strain relief should have a tight fit with
the dryer cabinet and be in a horizontal position. Do not
further tighten strain relief screws at this point.