AEG GLASS-GLASS AS-M 3 Series Installation Manual page 18

Hide thumbs Also See for GLASS-GLASS AS-M 3 Series:
Table of Contents

Advertisement

X
X
4 clamps mounting to the short frame
Clamp position:
; X =
0-250mm
Test load: positive 1200Pa / negative 1200Pa
AS-M1088-BH(M10) / HV
Design load: positive 3600Pa / negative 1600Pa
X
L
X
L
AEG GLASS GLASS MODULE INSTALLATION MANUAL
X
X
L
X
X
L
X
X
X
X
X
X
X
X
4 clamps overlapping to the short frame
Clamp position:
;
X = 150-250mm
Test load: positive 1800Pa / negative 1800Pa
AS-M1088-BH(M10) / HV
Design load: positive 3600Pa / negative 1600Pa
X
L
X
L
X
X
L
X
X
L
X
X
X
X
EN
GD202311 V1-23