Kenwood FL-180A Service Manual page 4

Wow-flutter meter
Hide thumbs Also See for FL-180A:

Advertisement

Measurement
accuracy
SPECIFICATIONS
+ (1 digit+reference time accuracy)
Maximum
input voltage
100 V (DC +AC peak)
Input monitor
Level monitor lamp goes on at 100 mV input or more.
(Flickers if input frequency exceeds
"9.999 kHz" with the GATE TIME button
released. Turns off if input frequency exceeds 55.00 kHz beyond the measure-
ment range with the GATE TIME button depressed.)
OUTPUT TERMINALS
Recording
output
signal
Signal frequency
3 kHz, 3.15 kHz
Accuracy
+5x 10°
Output voltage
0.2 Vrms+ 20%
(open output)
Output impedance
600 2+ 20%
(unbalanced)
Distortion factor
Less than 1% (600 2 terminated)
Drift output termi-
nal (DRIFT)
Output voltage
Approx. DC+1
V, for each
+1%
of frequency drift
Output impedance
600 2+ 20%
(unbalanced)
Scope output ter-
minal (TO SCOPE)
Output voltage
Approx. 3 Vrms of full scale
Output Impedance
600 0+20%
(unbalanced)
Recorder output ter-
minal (RECORDER)
Output voltage
Approx. DC 1 V of full scale
Output impedance
POWER REQUIREMENTS
Voltage
Power consumption
OPERATING TEMPERATURE
DIMENSIONS (WxHxD)
WEIGHT
ACCESSORIES
Connecting
cord with
plugs and
clips
600 2+ 20% (unbalanced)
AC 100/117/220+ 10%, 216
V~ 250 V, 50/60 Hz
Approx.
14 W
O0~40 °C
260 mm
x 150 mm
(171)
x 305 mm
(360)
(
) dimentions include protrusion from basic outline dimentions.
Approx. 5.2 kg
(CA-36)
1 piece
AC cord
1 piece
Instruction manual
1 copy
Replacement
fuse
2 pieces
2 pieces
* Circuit and rating are subject to change without notice due to developments in technology.