BUS address
32H:D7
D1/D2 Det
32H:D6
D1/D2 Manual set
32H:D5-D4 Internal feed-back-
clamp
33H:D7
Manual Gain AGC
33H:D6-D0 Manual Gain
34H:D7-D4 CGP start phase
34H:D3-D0 Width of CGP
35H:D7-D4 Threshold for DET.443
35H:D1-D0 Sync-tip-clamp-mode for
Y-input
36H:D7
CGP OUT control
36H:D6
C Trap of DCOMB
36H:D0
Mute
37H:D7
Y Noise
37H:D6
Y Noise Lim
37H:D5
Y Noise Gain
37H:D4
Y Noise canceler
37H:D3
CKILL Gain
37H:D2
C Noise lim
37H:D1
C Noise Gain
37H:D0
C Noise canceler
Feb./2005
Function
It is the distinction of D1/D2.
It is effective 32H:D6 when manual set.
Internal control is fixed with D1orD2.
When clamp set internal, it can set time constant.
It set ON/OFF of Peak-AGC Gain.
It is effective when it is ON.
It gives priority to Manual when this bit is ON. Therefore,
it can't get the effect of AGC.
It is effective when 33H(D7).
Gain becomes a fix.
It set start phase of CGP(Output of Terminal-73).
It set width of CGP(Output of Terminal-73).
It set threshold for DET.443.
It is easy to distinguish when a MAX side is chosen.
It is the control of limit-clamp to add under the input signal
at Y input.
Four kinds of switchings are possible.
ON:Always,limitter-clamp to add to Low-level of input is ON.
OFF:Always,limitter-clamp to add to Low-level of input is off.
AUTO1:It is ON in the no-signal and 'When Pedestal-Level
AUTO2:It is ON on no-signal.
It set action of CGP.
AUTO: It is output only when an input signal is set 11(D7 and
D6 on 00H).
Forced on: It is output to all the input.
It is ON, when you want reduce Cross-color and beat.
The Blanking period becomes mute.
It set f0 of Y-Noise-Canceler.
It usually uses on "0".
It set Limitter of Y-Noise-Canceler.
It set Gain of Y-Noise-Canceler.
It set ON/OFF of Y-Noise-Canceler.
It set the condition of CKILL Gain.
When it is set up in +6dB, Level which color disappears to
grows big. It uses "0" when weak electric density.
It set Limitter of C-Noise-Canceler.
It set Gain of C-Noise-Canceler.
It set ON/OFF of C-Noise-Canceler.
deviated greatly.'
Contents
TC90101FG
29