INSTALLATION GUIDE
Inhab
Energy
Smart Home
Energy Monitor
usa.siemens.com/InhabEM
INHABIT™ ENERGY INSTALLATION GUIDE
1

Advertisement

loading

Summary of Contents for Siemens Inhab Energy

  • Page 1 INSTALLATION GUIDE Inhab Energy ™ Smart Home Energy Monitor usa.siemens.com/InhabEM INHABIT™ ENERGY INSTALLATION GUIDE...
  • Page 2: Safety Information

    Improper installation or use of the equipment can be dangerous or even fatal. In no event shall Siemens be liable to you or any third party for any damages, either direct or indirect, arising from or related to any personal injury as a result of your failure to follow the safety information and instructions in this Installation Guide.
  • Page 3 Contact support at 1-800-241-4453 immediately. • Do not use the Siemens Inhab Energy in any manner other than specified in this installation guide, otherwise, the protection provided by the equipment may be impaired.
  • Page 4 Safety information WARNING • Do not position the Siemens Inhab Energy so that it is difficult to operate disconnecting devices or breakers. • Do not use 3rd party accessories or Current Transformers (CTs) with the Siemens Inhab Energy. The Inhab Energy and CTs are customized and integrated.
  • Page 5: Before You Get Started

    Before you get started The Siemens Inhab Energy is installed in a home’s electrical panel. The main breaker will need to be set to the off position, which will shut off all of the power in the home. However, the service entrance wires to the load center will remain energized and dangerous.
  • Page 6: What's In The Box

    What’s in the box The Siemens Inhab Energy contains the following items. If any of these items are missing or if you believe they’ve been damaged, contact support immediately. Inhab Energy monitor 2 Main 200A CTs with 22 AWG wire and...
  • Page 7 Energy monitor connections The energy monitor is the hub of the Siemens Inhab Energy. The screw terminalport for the wiring harness is located on the left-hand side of the monitor. The screw terminal ports across the top of the monitor are the inputs for the 50A Branch Current Transformers (CTs) (the bundle may have come with 8 or 16 CTs, or none at all).
  • Page 8 Once the app is downloaded, you’ll be prompted to create an account if you don’t have one. Also, if you plan to connect the Inhab Energy to the internet via Wi-Fi, this is a great time to use a phone to check the signal strength of the Wi-Fi network next to the electrical panel in the home.
  • Page 9 Note that these may be located outside of the panel in which you’re installing the Inhab Energy. Next, remove any screws holding the cover to the panel and remove the cover to access the circuit breakers and service entrance wires to...
  • Page 10 Find a place that works. If the Inhab Energy is to be mounted on a DIN rail, the monitor has two threaded screw holes to attach mounting hardware using two M3 screws and lock washers (sold seperately).
  • Page 11 Step 4: Prepare for Internet connection The Inhab Energy is capable of connecting to the internet either via a wired LAN connection, a Wi-Fi connection, or both. If both are implemented, the Inhab Energy will prioritize wired LAN. If a wired LAN is unavailable, the Inhab Energy will attempt to connect over Wi-Fi.
  • Page 12 RJ45 connector from a router, switch, or modem to the electrical panel. Then, use a screwdriver to remove a knockout from the electrical panel. Next, feed the cable through the hole to the Inhab Energy and plug it in the socket on the right-hand side of the energy monitor marked...
  • Page 13 Step 4(b): Prepare for Wi-Fi connection This step is to prepare for a wireless internet connection. To connect to the internet via wired LAN, see Step 4(a). Use a screwdriver to remove a knockout from the electrical panel. Now, feed the antenna through the hole. Then, screw the antenna assembly cable to the right-hand side of the energy monitor in the coaxial connector marked .
  • Page 14 The Inhab Energy will be installed differently depending on whether the solar is a break- er-fed or a line-side tap installation. The Main CTs that connect to the mains will provide net metering out of the box —...
  • Page 15 To avoid clutter, unscrew the 22 AWG wires from the screw terminals, cut them to size, and reattach them ensuring the black and white wires match the icons on the front of the Inhab Energy. Meter Breakers...
  • Page 16 To avoid clutter, unscrew the 22 AWG wires from the screw terminals, cut them to size, and reattach them ensuring the black and white wires match the icons on the front of the Inhab Energy. front of the Inhab Energy...
  • Page 17 To avoid clutter, unscrew the 22 AWG wires from the screw terminals, cut them to size, and reattach them ensuring the black and white wires match the icons on the front of the Inhab Energy. Inverter...
  • Page 18 Step 6: Plug in the voltage sensing wire harness Insert the 7.6mm screw terminal plug of the power supply wiring harness with four 16 AWG wire leads into the port of the left side of the energy monitor until it clicks into place securely.
  • Page 19 If wiring to an in-use breaker, use the splicing wires / wire nuts included with the Inhab Energy for breakers rated up to 15A. Any ampacity rating may be used if the splicing wire guage matches the existing wire and meets applicable electric codes.
  • Page 20 15A breakers as well as the number of Main CTs installed in Step 5. Go to the step below based on the system. If you’re unsure, contact Siemens Support and we’ll help you through it. Step 7(a) Common in split phase homes •...
  • Page 21 Step 7(a): Two empty breakers and two Main CTs Common in split phase homes Secure the White (N) and Blue (L3) wires from the wire harness to the neutral bus bar. Turn off two vertically adjacent (stacked) single pole breakers and secure the Black (L1) and Red (L2) wires from the harness to each of the hot leads from each breaker.
  • Page 22 Step 7(b): No empty breaker and two Main CTs Common in split phase homes Secure the White (N) and Blue (L3) wires from the wire harness to the neutral bus bar. Turn off two vertically adjacent (stacked) 15A single pole breakers and remove their wires.
  • Page 23 Step 7(c): Three empty breakers and three Main CTs Common in 3-phase commercial systems Secure the White (N) wire from the wire harness to the neutral bus bar. Turn off three vertically adjacent (stacked) single pole breakers and secure the Black (L1), Red (L2), and Blue (L3) wires from the harness to each of the hot leads from each breaker.
  • Page 24 Step 7(d): No empty breaker and three Main CTs Common in 3-phase commercial systems Secure the White (N) wire from the wire harness to the neutral bus bar. Turn off three vertically adjacent (stacked) 15A single pole breakers and remove their wires. Connect one of the breaker wires to the Black (L1) harness wire and a splicing wire with a wire nut.
  • Page 25 Branch current transformers If the Inhab Energy has Branch CTs, open the clasps on the CTs and place each clamp around the non-neutral leg from the breaker that is to be monitored. Then shut the clasps to secure the CTs. Then, insert the screw terminal plugs into the ports on the top of the energy monitor.
  • Page 26 Step 8 (continued): A note about multi-pole breakers If 2- or 3-pole breakers are to be monitored, we recommended that one CT be used for on each pole; however, to conserve the number of CTs, a single CT can be used. To use a single CT, clasp the clamp around either one of the non-neutral leads coming off the breaker (it doesn’t matter which).
  • Page 27 Step 8 (continued): A note about solar monitoring For the Inhab Energy to be able to calculate how much energy from the system is going to and from the grid, Branch CTs will need to be connected to the incoming leads from the inverter regardless of whether the solar is a breaker-fed or a line-side tap installation.
  • Page 28 Step 9: Take a photo of your system Before replacing your panel cover, take photos of the installation in case you need to contact support. INHAB™ ENERGY INSTALLATION GUIDE...
  • Page 29 You should hear a power up tone from the Inhab Energy to confirm it has power. Then, close the panel. Once the panel cover is replaced, the antenna connector and screw terminal ports on the Inhab Energy will not be accessible.
  • Page 30: Step 11: Complete Setup

    Step 11: Complete setup Return to the Siemens app to continue the setup process that you began in Step 1 by scanning the QR code on the Inhab Energy or Getting Started Guide to connect the Inhab Energy to the internet via Wi-Fi or wired LAN connection.
  • Page 31: Troubleshooting Tips

    Here are some of our most frequent troubleshooting tips. For more help, call the Siemens Technical Support number at 1-800-241-4453. The Siemens app is not finding the Inhab Energy after I’ve installed it. • Ensure the Inhab Energy has power: - Check for a flashing Wi-Fi light.
  • Page 32 Try running the configuration at night. • When configuring the Inhab Energy with the App, make sure that there is a discernible load on the system. Try turning on an oven, A/C, or dryer.
  • Page 33 Inhab Energy LED lights The Inhab Energy has two LED lights on the front of the energy monitor, that can help troubleshoot the status of the internet connection and whether or not the monitor has power. Wi-Fi (and indication of power) Slowly Flashing Green Not connected to router.
  • Page 34: Technical Details

    Technical Details Energy Monitor (INHEM1216) Supported system configurations: • Single phase, 2-wire systems • Single-split phase, 3-wire systems • 3-phase, 4-wire Wye systems with earthed (TN or TT) neutral (no-Delta) • Fuse: 260VAC/0.3A (Fusible resistor: 10E, 1W, 5%, TH) • Maximum voltage sense range: 264VAC L-N per channel Power usage: < 3 Watts •...
  • Page 35: Information De Sécurité

    Une installation ou une utilisation incorrecte de l‘équipement peut être dangereuse, voire mortelle. Siemens ne pourra en aucun cas être tenu responsable envers vous ou un tiers pour tout dommage, direct ou indirect, pour une blessure personnelle résultant de votre non-respect des informations et instructions de sécurité...
  • Page 36 • L’Siemens Inhab Energy doit être câblé à l’aide de fils de cuivre 16AWG, 600V, UL1015, 105° C (ou plus) • Il est recommandé de câbler l’Siemens Inhab Energy au disjoncteur le plus proche de l’appareil.
  • Page 37 Information de sécurité AVERTISSEMENT • Ne placez pas l’Siemens Inhab Energy de manière à ce qu’il soit dicile d’actionner des dispositifs de déconnexion ou des disjoncteurs. • N’utilisez pas d’accessoires tiers ou Current Transformateurs (TC) avec l’Siemens Inhab Energy. Le Inhab Energy et les CT sont personnalisés et intégrés.
  • Page 38 An instrument should only be used at or below its rated measurement category and voltage. For example, the Inhab Energy Monitor is CAT III rated and can be used to monitor CAT I, CAT II, and CAT III circuits.
  • Page 39 (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modifications not expressly approved by Siemens void the user’s authority to operate the equipment.