Setup - GE TONOPORT V Operator's Manual

Ambulatory blood pressure system
Hide thumbs Also See for TONOPORT V:
Table of Contents

Advertisement

3

Setup

Some Basic Facts on Battery Power
TONOPORT V is either powered by two rechargeable
Nickel Metal Hydrid batteries (NiMH) or by two alkaline
batteries. The device must be set to the power source used
(see section "Insert Batteries" below). The device also
contains a Lithium cell that powers the clock. The
Lithium cell can only be replaced by a service technician.
The capacity of two fully charged or new batteries is
sufficient for a minimum of 30 hours of operation or for
200 measurements.
The capacity of rechargeable batteries decreases with
age. If the capacity of fully charged batteries is
considerably less than 24 hours, the batteries must be
replaced.
Caution
Equipment damage —
– Only use the original rechargeable, size AA Nickel
Metal Hydrid batteries (from manufacturers such
as Sanyo, Panasonic, Energizer, Duracell, Varta,
or GP) with a capacity > 1500 mAh or size AA
high-rate discharge alkaline batteries (such as
Panasonic Evoia, Energizer Ultimate, Duracell
Ultra, Duracell Power Pix, or Varta maxtech).
– Charge the NiMH batteries to capacity before
using them for the first time.
– Recharge the NiMH batteries immediately after
use and do not leave batteries uncharged.
– Use only the original charging unit to recharge
the NiMH batteries.
– Do not attempt to recharge the alkaline batteries.
– If the TONOPORT V will not be used for one
month or more, remove the (rechargeable)
batteries from the device.
– Batteries must not be disposed as unsorted
municipal waste and must be collected separately.
Please contact an authorized representative of the
manufacturer for information concerning the
decommissioning of the batteries.
Insert Batteries
Note
Switch TONOPORT V off before inserting the
batteries. To do so, slide the ON/OFF switch (10,
Fig. 2-1) to the left while looking at the display.
12
Setup
 Hold TONOPORT V as shown in Fig. 3-1 and slide
the lid of the battery compartment open (approx.
1 cm).
Fig. 3-1 Opening the battery compartment
It is not possible to open the lid more than about 1 cm
which is just enough to reach the ON/OFF switch. To
replace batteries, you must take off the lid (pull upward).
 Place the two batteries in the compartment as indicat-
ed by the symbols.
Select Energy Source
 Turn on the BP monitor. The switch is located inside
the battery compartment. Slide the switch to the right,
while looking at the display.
 Wait for the time to be displayed.
 Push
INFO
six times: the display shows "H 6".
START
STOP
INFO
 Push
: the display will show "AAAA" when the
START
START
STOP
STOP
BP monitor is set up for rechargeable NiMH batteries
(as shipped) and "bbbb" when it is set up for alkaline
batteries.
 Confirm the displayed information with
change the selection with
selection with
 Next the BP monitor will briefly display the capacity
of the inserted batteries. "A 100", for instance, means
that the rechargeable batteries have a capacity of
100%, i.e., they are fully charged. "b 50" means that
TONOPORT V
INFO
and confirm the new
START
STOP
INFO
.
START
START
STOP
STOP
2001589-085 Revision G
INFO
START
START
or
STOP
STOP

Advertisement

Table of Contents
loading

Table of Contents