Available languages

• Use figures from the Tightening Torque
EN
Chart to guide your selection of torque
clutch setting. (See the following tighten-
ing torque chart)
2. Press the OK button to accept the select-
ed torque clutch setting.
• The control panel will stop flashing and
light up.
CAUTION:
• You must press the OK button in order
for the selected setting to take effect.
• Be sure to verify the new value after
changing the setting.
[EYFLF]
Tightening Torque Chart (for
Reference Use)
The values illustrated on this chart were mea-
sured under the conditions described below
and are provided for reference purposes.
Actual tightening torque varies with ambient
conditions (the particular bolt being tightened,
hardware being used, method of holding the
bolt in place, etc.).
[Fig.16]
Measurement conditions
• Temperature: Room temperature (20 °C/68 °F)
[EYFLF]
Setting the snug point detection level
[Fig.17]
1. Press the A button.
• The snug point detection level setting
value will be displayed.
[Fig.18]
2. Press the
best snug point detection level for the
work you're performing.
3. Press the OK button to accept the number
of torque stages and the snug point detec-
tion level.
The tool's panel will flash and then light up
continuously.
Snug point detection level guidelines
[Fig.19]
[Fig.20]
and
buttons to set the
CAUTION:
• The setting will not be changed until you
press the OK button.
• After changing the setting, be sure to
check the new setting value. (See
"Checking Tool Settings.")
• Set the snug point detection level from
"L1." Setting the snug point detection
level from "L7" may result in cracking or
deformation of the target material.
• If the tool stops before the snug point at
snug point detection level "L1," set the
snug point detection level to "L7."
• Changing the snug point detection
level from "L1" to "L7" may increase the
torque. Set the number of torque stag-
es again after making this change.
[EYFLF]
IMPORTANT INFORMATION:
• Pressing the A button toggles the display
between the snug point detection level
setting value and the number of torque
stages setting value.
• The tool ships with the snug point detec-
tion level set to "L1."
• When the number of torque stages has
been set as shown below, the snug point
detection level cannot be switched from
"L1" to "L2 ~ L7."
Model
EYFLF1
EYFLF2
[EYFLF]
Cross thread reduction function
The tool runs in reverse approximately 360°
before running forward to assist in the align-
ment of the threads to help reduce cross
threads.
1. Set the tool to setting configuration mode.
(See page 19.)
2. Press the D button once.
The cross thread reduction function set-
ting value will be displayed.
3. Press the
setting to ON or OFF.
Display
R0
R1
‒ 20 ‒
Number of torque stages
setting
1 to 40
1 to 40
and
buttons to change the
Function
OFF
ON