Hiperface Serial Link - ABB FEN-11 User Manual

Absolute encoder interface
Hide thumbs Also See for FEN-11:
Table of Contents

Advertisement

HIPERFACE serial link

HIPERFACE encoders: The output channel that leads when the drive runs forward
should be connected to FEN-11 input SIN, the output channel that trails to FEN-11 input
COS.
Note: If an SSI encoder provides incremental signals that correspond to SIN and COS
provided by HIPERFACE encoders (shown in the figure below), the cosine channel
should be inverted in order to meet the requirement for incremental signals used with
SSI serial link (shown in the figure above).
Incremental signals used with HIPERFACE serial link
2.5 V
1
Encoder channel: SIN
2
Encoder channel: COS
SIN
0.5 V
1
COS
Installation 33
2
0.5 V