  • Page 1 Introduction Device description Installation & operation SIMATIC RTLS Technical specifications Localization systems SIMATIC RTLS4083T Approvals Operating Manual 05/2023 C79000-G8976-C646-05...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Technical specifications ........................21 RTLS4083T technical specifications..................21 RTLS charging station technical specifications..............22 Technical specifications of the mounting clip RTLS4083T ............ 23 Technical specifications of the RTLS4083T Power mounting clip .......... 23 Approvals ............................. 25 SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 4 Table of contents SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 5: Introduction

    Siemens AG: SIMATIC RTLS Industry Online Support In addition to the product documentation, the comprehensive online information platform of Siemens Industry Online Support offers support at the following Internet address: (https:// support.industry.siemens.com/cs/start?lc=en-US) Apart from news, there you will also find: •...
  • Page 6 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions form one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
  • Page 7 Introduction To ensure that you are always informed about product updates, subscribe to the Siemens Industrial Security RSS feed at: https://www.siemens.com/cert (https://www.siemens.com/cert) Note on firmware/software support Check regularly for new firmware/software versions or security updates and apply them. After the release of a new version, previous versions are no longer supported and are not maintained.
  • Page 8 Introduction SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 9: Device Description

    Device description Characteristics SIMATIC RTLS4083T Characteristics ① Design Status indicator L1 (LED) ② Function key F1 ③ Display General The transponder is a mobile device for localiza‐ tion in the RTLS localization system. It sends po‐ sition data to gateways which transmit the data to the Locating Manager server.
  • Page 10: Led Status Indicator, Display & Function Key

    Manager, you can configure a transponder parameter to define the threshold value below which the battery voltage is defined as too low for operation, a "low power" message is generated and the LED flashes red. Refer to the notes in the section "RTLS4083T operation (Page 17)". SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 11: Dimension Drawing Of Rtls4083T

    Device description 2.4 Dimension drawing of RTLS4083T Dimension drawing of RTLS4083T Figure 2-1 Dimension drawing of SIMATIC RTLS4083T - All dimensions are given in millimeters SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 12: Dimension Drawing Of Rtls Charging Station

    Device description 2.5 Dimension drawing of RTLS charging station Dimension drawing of RTLS charging station Figure 2-2 Dimension drawing of SIMATIC RTLS charging station (not included with the product) - All dimensions are given in millimeters SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 13: Dimension Drawing Of Rtls4083T Mounting Clip

    Device description 2.6 Dimension drawing of RTLS4083T mounting clip Dimension drawing of RTLS4083T mounting clip Dimension drawing of SIMATIC RTLS mounting clip for RTLS4083T (not included with the product) - All dimensions are given in millimeters SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 14: Dimension Drawing Of Rtls4083T Power Mounting Clip

    2.7 Dimension drawing of RTLS4083T Power mounting clip Dimension drawing of RTLS4083T Power mounting clip Figure 2-3 Dimension drawing of SIMATIC RTLS Power mounting clip for RTLS4083T (not included in product package) - All dimensions are given in millimeters SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 15: Installation & Operation

    This applies to lithium-ion batteries: • Do not squeeze • Do not heat and do not burn • Do not short-circuit • Do not disassemble • Do not immerse in liquid - the battery may crack or burst SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 16 (de- sensing). This is true, for example, for the 2.4 GHz ISM band and PULSE in the UWB channel 5. SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 17: Operation

    Locating Manager. The limit above which the transponder sends this message is configurable. In this case, the transponder must be fully recharged within 3 months to avoid deep self-discharge and damage to the battery. SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 18: Rtls4083T Operation With Power Mounting Clip

    Improper opening or repairing of the devices may result in serious risks for the user. Opening the devices without permission renders the warranty of the Siemens AG null and void. Do not clean the devices with liquids or abrasive, caustic or flammable cleaning products.
  • Page 19 Read also the descriptions of the operating states of the transponder in section "LED status indicator, display & function key (Page 10)". SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 20 Installation & operation 3.4 Charging instructions for the RTLS charging station SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 21: Technical Specifications

    Supply voltage 3.7 V lithium ion rechargeable battery (1950 mAh) Service life (at 20 ℃) Standby: 1 year Operation: 100% UWB localization at 1 second: 6 months Display updates every 10 seconds without localization: 25 days     Permitted ambient conditions SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 22: Rtls Charging Station Technical Specifications

    See Permitted ambient conditions of the RTLS4083T trans‐ ponder     Design, dimensions, weights and connectors of RTLS charging station Dimensions (L x W x H) 298.4 mm x 180.6mm x 83.2 mm Weight 1092 g Degree of protection IP00 Enclosure Plastic enclosure (PC 10 GF) Color Titanium gray SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 23: Technical Specifications Of The Mounting Clip Rtls4083T

    10 mm length (not included in product package) Make sure to observe the polarity marked on the Power mounting clip. Supply voltage 19 ... 25 V DC Rated voltage 24 V DC Power consumption Maximum 8 W SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 24 Technical specifications 4.4 Technical specifications of the RTLS4083T Power mounting clip   6GT2790-0DE40 Current consumption Maximum 0.3 A Verification of suitability SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 25: Approvals

    (TR CU) USA (FCC) This device complies with part 15 of the FCC rules. Alternative: FCC ID: XXXXYYZZZZ IC: XXXXYYZZZZ Canada (ISED) This device complies with Industry Canada licence-exempt RSS stand‐ ard(s). SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 26 ANATEL: XXXXYYZZZZ tel.gov.br). Importer UK: Siemens plc, Sir William Siemens House, Princess Road, Manchester M20 Mexico (NOM) La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia per‐...
  • Page 27 Siemens plc, Manchester M20 2UR You can find the current UK Declaration of Conformity for these products on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/en/en/view/109801531). The SIMATIC RTLS products described in this document meet the requirements of the following directives/regulation: •...
  • Page 28 Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments • EN 61000-6-4 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments SIMATIC RTLS4083T Operating Manual, 05/2023, C79000-G8976-C646-05...
  • Page 29 3.2 of the Directive 2014/53/EU; Part 2: Requirements for UWB location tracking FCC information Siemens SIMATIC RTLS4083T (MLFB 6GT2700-5DC15); FCC ID SCF4083T02 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:...
  • Page 30 Approvals NOM información Siemens SIMATIC RTLS4083T (MLFB 6GT2700-5DC15); IFT RCPHMR22-2325 La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada.