Article number
Source/sink input
Input characteristic curve in accordance with IEC
61131, type 3
Digital input functions, parameterizable
•
Freely usable digital input
•
Probe
•
Digital input with time stamp
•
Counter
Digital input with oversampling
•
Input voltage
•
Type of input voltage
Rated value (DC)
•
•
for signal "0"
for signal "1"
•
•
permissible voltage at input, min.
•
permissible voltage at input, max.
Input current
•
for signal "1", typ.
Input delay (for rated value of input voltage)
•
Minimum pulse width for program reactions
for standard inputs
–
parameterizable
–
with "0" to "1", typ.
–
with "1" to "0", typ.
for interrupt inputs
parameterizable
–
for technological functions
–
parameterizable
with "0" to "1", typ.
–
–
with "1" to "0", typ.
Cable length
shielded, max.
•
unshielded, max.
•
Digital outputs
Type of digital output
integrated channels (DO)
Current-sinking
SIMATIC Drive Controller
Equipment Manual, 11/2022, A5E46600370-AC
6ES7615-4DF10-0AB0
P-reading
Yes
Yes; Max. 20 (X122/X132) + max. 8 (X142)
Yes; Max. 8 (X122/X132) + max. 8 (X142)
Yes; Max. 8 (X142); e.g. for probes
Yes; Max. 8 (X142); event/cycle duration measurement
Yes; Max. 8 (X142); 32-fold oversampling
DC
24 V
-3 to +5V
+15 to +30 V
-30 V
30 V
4 mA
5 µs for X122/X132/X142 (DI/DQ as DI; for X142 with filter setting 1
µs)
No; For X122/X132
For X122/X132: 10 µs (DI) / 5 µs (DI/DQ as DI)
For X122/X132: 30 µs (DI) / 5 µs (DI/DQ as DI)
Yes; identical to those for technological functions
Yes; For X142, additionally adjustable input filter: 1 µs / 125 µs
5 µs; For X142; HW delay
5 µs; For X142; HW delay
30 m; For technological functions: Shielding of the DI recommended
depending on the requirements
30 m
Transistor
16; max. depending on parameterization
Yes; With High Speed output
Technical specifications
6ES7615-7DF10-0AB0
69