Accessories And Replacement Parts - Siemens SITRANS LG260 Operating Instructions Manual

Guided wave radar
Hide thumbs Also See for SITRANS LG260:
Table of Contents

Advertisement

Storage and transport
temperature
Display and adjustment
module
External display and
adjustment unit
External display and ad-
justment unit with HART
protocol
DISADAPT
Flanges
Electronics module
10
Unless otherwise indicated, the packages must be stored only under
the following conditions:
Not in the open
Dry and dust free
Not exposed to corrosive media
Protected against solar radiation
Avoiding mechanical shock and vibration
Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
Relative humidity 20 ... 85 %
3.4

Accessories and replacement parts

The display and adjustment module LG Local Display Interface is
used for measured value indication, adjustment and diagnosis. It can
be inserted into the sensor and removed at any time.
You can find additional information in the operating instructions
manual "LG Local Display Interface" (Document-ID 43838).
The LG Remote Interface is an external display and adjustment unit
for sensors with single chamber housing and Ex-d double chamber
housing.
It is suitable for measured value indication and adjustment of sensors
and is connected to the sensor with a four-wire standard cable up to
50 m (164 ft) long.
You can find additional information in the operating instructions
manual "LG Remote Interface".
The LG Remote Interface is suitable for measured value indication
and adjustment of sensors with HART protocol. It is looped into the
4 ... 20 mA/HART signal cable.
You can find additional information in the operating instructions
manual "LG Remote Interface".
The adapter "DISADAPT" is an accessory part for sensors with dou-
ble chamber housings. It enables the connection of the exterbal dis-
play and adjustment unit to the sensor housing via an M12 x 1 plug.
You can find further information in the supplementary instructions
"Adapter DISADAPT".
Screwed flanges are available in different versions according to the
following standards: DIN 2501, EN 1092-1, ASME B 16.5, JIS B 2210-
1984, GOST 12821-80.
You can find additional information in the supplementary instructions
manual "Flanges according to DIN-EN-ASME-JIS" (Document-ID
47574).
The electronics module SITRANS series LG is a replacement part for
TDR sensors of SITRANS series LG. There is a different version avail-
able for each type of signal output.
SITRANS LG260 - Operating Instructions
PBD-51041057