4.6 Programming the Ident profile
Table 4- 68 Result of GET-BLACKLIST
Name
NUM IDS
TAG_DATA
TAG_DATA[1]
TAG_DATA[2]
...
TAG_DATA[n]
Table 4- 69 READ-CONFIG
Parameter
CMD
OFFSETBUFFER
RXREF
Table 4- 70 WRITE-CONFIG
Parameter
CMD
OFFSETBUFFER
LEN_DATA
CONFIG
TXREF
Structure of the configuration data attachment of "WRITE-CONFIG"
For RF600 and RF18xC/RF18xCI:
• When CONFIG = 0x01:
Reset_Reader; LEN_DATA = 0x00
• When CONFIG = 0x03:
When replacing a module, it is possible to read all the configuration data from the
CM/reader and to store it on the controller. When the module is replaced, this data
can then be loaded on the reader from the controller. The command "WRITE-
82
Type
INT
IID_IN_I_80[
n]
IID_IN_I_80
Reserved
SINT
ID_Len
SINT
EPC_ID
SINT[62]
IID_IN_I_80
...
IID_IN_I_80
Comment
Number of MDS
Length of EPC ID
EPC-ID
Value / description
0x61
Offset in the "RXREF" receive buffer
Read reset parameters
Value / description
0x78
Offset in the "TXREF" send buffer
0x01 ≙ communication reset, no configuration data
Length of the parameter data
0x02 ≙ no communication reset, configuration data to be sent
0x03 ≙ communication reset, configuration data to be sent
0x80 ≙ no communication reset, individual parameters
Configuration data to be sent