Parameter description
6.F Running History Record
Code
Description
Type of latest
FF.00
fault
SINAMICS V50 converter
64
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
Setting range
0: NULL
1: Uu1 bus
undervoltage
2: OC1 Acc.
overcurrent
3: OC2 Dec.
overcurrent
4: OC3 Constant
speed overcurrent
5: Ou1 Acc.
overvoltage
6: Ou2 Dec.
overvoltage
7: Ou3
overvoltage in
constant speed
8: GF Ground
fault
9: SC Load Short-
circuit
10: OH1 Heatsink
overheat
11: OL1 Motor
overload
12: OL2 Drive
overload
13: EF0
communication
fault
14: EF1 external
terminal fault
15: SP1 Input
phase failure or
input phases
unbalance
16: SPO Output
phase failure or
Unbalance
Default
Modify
NULL
*
Modbus
Address
1000H