ARD-FPBEW2-H3 Fingerprint Reader, Multiclass
3.5

RS485 connection

3.6

Resetting network settings

1.
2.
3.
4.
5.
3.7

Restoring the factory defaults

This will delete all data and root certificate on the device and reset the settings.
1.
2.
3.
NOTE
Bosch Access Systems GmbH
Turn the power on.
Press the network reset button on the rear of device until the device restart
automatically.
Connect the device with default values.
TCP/IP address: DHCP address assignment (If DHCP address assignment is fails,
169.254.x.x will be set.)
Server mode: Disabled
RS-485: PC connection, 115200 bps
Change the TCP/IP address or RS-485 information.
Turn the power off later on and then check the network setting is properly.
Turn the power on.
Press the reset button three times quickly.
When the yellow LED is blinking, press the reset button again.
If there is no root certificate on the device, you cannot restore the factory defaults.
14 - 485 TRXN (RxTx-)
15 - 485 TRXP (RxTx+)
16 - 485 GND
Installation manual
Installation | en
Yellow (Black stripe)
Blue (White stripe)
White (Black stripe)
Control device
2022-06 | v01 |