Mounting the pipe-suspended hangers 2
3
1.
Loosen the cap securing screw
and turn the cap to the left to
remove it from the hanger.
Cap
Loosen
2.
Spread apart the hanger and
match the polarity indication
on the duct with the polarity
indication on the hanger.
Factory Line 20 duct
3.
Fit the duct into the hanger,
and then turn the cap to the
right and tighten the securing
screw in order to secure the duct.
Caution
Turn the cap until it is fully locked.
 Not doing so may cause the duct to drop.
Mounting the pipe-suspended hangers 3
4
1.
Supplying power via the pipe-suspended hangers(method for
bringing in the power supply)
Route the cable from the ceiling into the pipe. When doing this,
it is easier if the cable is passed through the pipe before
securing the Factory Line 20 duct in the hanger.
Pipe
2.
Following the same procedure for Step
hanger, and then fix it with the cap.
Hanger
Polarity indication
Mount the hanger from
the polarity indication
side of the duct.
Match the polarity
indications.
・Use single-conductor cables of 1.6 or 2.0 m㎡ in size.
Make wire connections with careful attention so 
that cables will not be bitten or damaged.
 Not doing so may result in electric shocks or fire.
Tighten.
5
3
, fit the duct in the
Cap
Pipe
Hanger
Factory Line 20 duct
Cable
Caution
Cable routing hole
Cable
fit the cap

Advertisement

loading