Figure 2.19 Connecting Hybrid Cable (2); Table 2.4 Hybrid Cable Color Map - Samsung Smart MBS RRH-C2A Installation Manual

Table of Contents

Advertisement

CHAPTER 2. Installation of RRH-C2A
RRH DC SPD Terminal
(Alpha)
F7
F8
- +
- +
-48 V
-48 V
RTN
RTN
Breaker
F7
RRU
RRU
#0
Capacity
32A
Return
White/Red stripe
-48 V
Red
2-26
RRH DC SPD Terminal
F9
F10
F11
- +
- +
- +
-48 V
-48 V
-48 V
RTN
RTN
RTN
Reserved
F8
F9
F10
RRU
RRU
RRU
#1
#2
#3
32A
20A
20A

Figure 2.19 Connecting Hybrid cable (2)

Table 2.4 Hybrid Cable Color Map

Group 0
Group 1
(1.9 GHz)
(800 MHz)
White/Black stripe
Black
(Beta)
F12
F13
F14
- +
- +
- +
-48 V
-48 V
-48 V
-48 V
RTN
RTN
RTN
Reserved
F11
F12
F13
F14
RRU
RRU
RRU
RRU
#4
#5
#6
#7
32A
32A
20A
20A
Group 2
(2.5 GHz)
White/Blue stripe
Blue
RRU 0
(-)
RRH DC SPD Terminal
(Gamma)
F15
F16
F17
F18
- +
- +
- +
- +
-48 V
-48 V
-48 V
RTN
RTN
RTN
RTN
Reserved
F15
F16
F17
RRU
RRU
RRU
#8
#9
#10
32A
32A
20A
Group 3
(2.5 GHz)
White/Brown stripe
Brown
© SAMSUNG Electronics Co., Ltd.
F18
RRU
#11
20A