4 Administration

Information on status diagnostics for HiPath HG 1500 such as DSS, PPP , Firewall,
HFA client, H.323, vCAPI, etc. is contained in the HiPath HG 1500 Administrator
Manual under Customer trace.

4.1 Tracing with development trace

Development trace must be deactivated when HiPath HG 1500 is in operation.
You must contact Development if you have problems or queries relating to develop-
ment trace.
Note that all three traces for the board must be saved in the event of errors, i.e., the:
development trace,
customer trace and
error memory.
If system crashes have occurred in connection with the board, make sure that you
also produce a "stack dump" and submit it together with the traces to the responsible
Development department.
The traces and the stack dump can withstand a reset, but are lost in the event of a
power failure.

4.2 Determining the firmware version of the board

The firmware version of the board can be determined by dumping a memory area
(possible in the Developer level of Assistant Xpress @LAN/HG 1500).
Step
1.
Switch to the developer mode of Assistant Xpress @LAN/HG 1500.
2.
Create a dump of the KDS (switches the menu items to developer mode).
3.
Call up the "Service" menu and select "Receive and save a memory area".
4.
Hex address FE000000 and size: Enter 20.
5.
Enter a file name: e.g., FW.txt
The file will now contain the version number of the firmware.
A31003-K5020-S100-6-7620