Intellivox DDC | Installation Manual | Introduction Introduction. This paper describes the factory recommended installation procedure for the Bosch Security Systems’ Intellivox range of controlled loudspeaker-arrays. This type of loudspeaker-array is equipped with an on- board Digital Signal Processor (DSP) module. This...
Intellivox column should be mounted in a position exactly perpendicular to the listening plane. Contrary to a conventional ‘low Q’ loudspeaker system, minor mechanical misalignment may lead to a degraded coverage and intelligibility. Bosch Security Systems | July 2003...
Page 6
In case the Intellivox is installed outside or in another environment with a high expected humidity, the electronics should be treated with an insulation substance to prevent defects due to condensing moisture. If specially ordered, this can be done during the manufacturing process. Bosch Security Systems | July 2003...
Fig 2. Refer to chapter to Fig 3 (right side) can be found at the rear side of the 3.1 for ordering info. panel that covers the connector compartment. Fig 2 WAGO massive to stranded wire clamp. Bosch Security Systems | July 2003...
Page 8
Fig 5. The blade of the screwdriver should be inserted far enough into the connector. The metal spring of the cage clamp, which is visible from the side of the connector, Bosch Security Systems | July 2003...
0.75 - 1.0 mm top side and one at the bottom and one in the center position if applicable. The horizontal angle of the swivel brackets can be secured by the Table 2 PVC insert sizes. Bosch Security Systems | July 2003...
In this case extra attention should be paid As mentioned earlier all enclosure dimensions refer to to the following aspects: the Intellivox-2c. Other models or custom supplied Fig 7 LBC 3253/00 Intellivox-2c dimensions, all measures in mm Bosch Security Systems | July 2003...
5. Remove the front grill(s) of the Intellivox before mounting the unit and remove the protection foam. This can be accomplished by gently lifting the grill at the positions of the ‘snap-in’ fittings which hold the grill. Bosch Security Systems | July 2003...
DGND should not be connected to any other situations where the standard class 2 insulation is ground pin (GND or AGND) on the chassis. not sufficient (fire, moisture etc.). Always connect the IEC ground terminal. Bosch Security Systems | July 2003...
Page 13
• AGND should not be connected to any other according to Fig 9. ground pin (GND or DGND) on the chassis. Fig 8 Ground configuration of the Intellivox chassis. Fig 9 Standard grounding configuration Bosch Security Systems | July 2003...
Page 14
GND pin of the terminal block (see Fig 11). Fig 10 Grounding configuration with totally decoupled audio ground Fig 11 Grounding configuration with low frequency decoupled audio ground Bosch Security Systems | July 2003...
Page 15
(as with unbalanced outputs). Degraded CMRR can also be caused by poor quality the capacitors to enhance the performance of the filter. cable due to asymmetrical capacitive properties of the core. Bosch Security Systems | July 2003...
(DGND). sacrificing safety or emission, although a minor degradation of the immunity can be expected which is depending on the configuration chosen. Fig 14 Structure of the RS-485 network Bosch Security Systems | July 2003...
Page 17
This fact, in combination with the relative low baud-rate, makes the network very tolerant to stub lengths or improper termination. Bosch Security Systems | July 2003...
Page 18
RS-485 B (+receive) RS-485 Z (-send) +9 V +9 V DC Table 7 RS-232 pin description of the RS-232 to RS- Table 8 RS-485 pin description of the RS-232 to RS- 485 adapter. 485 adapter Bosch Security Systems | July 2003...
This means that the microphone should be kept away from direct sound sources such as talking people, outlets of the air conditioning system or other loudspeakers. Bosch Security Systems | July 2003...
Page 20
Figure 18 and 19 show the wiring configurations for the sensor with the two cable types. Fig 18 Wiring configuration at the sensor using asymmetrical cable type Fig 19 Wiring configuration at the sensor using RS- 485 network cable type Bosch Security Systems | July 2003...
All manuals and user guides at all-guides.com EN | 22 Intellivox DDC | Installation Manual | Appendix 3.5 Intellivox dimensions of the different models. Fig 20 LBC 3251/00 Intellivox-1b dimensions, all measures in mm. Bosch Security Systems | July 2003...
Page 22
All manuals and user guides at all-guides.com EN | 23 Intellivox DDC | Installation Manual | Appendix Fig 21 LBC 3252/00 Intellivox-2b dimensions, all measures in mm Bosch Security Systems | July 2003...
Page 23
All manuals and user guides at all-guides.com EN | 24 Intellivox DDC | Installation Manual | Appendix Fig 22 LBC 3252/10 Intellivox-2b dimensions, all measures in mm Bosch Security Systems | July 2003...
Page 24
All manuals and user guides at all-guides.com EN | 25 Intellivox DDC | Installation Manual | Appendix Fig 23 LBC 3253/00 Intellivox-2c dimensions, all measures in mm Bosch Security Systems | July 2003...
Page 25
All manuals and user guides at all-guides.com EN | 26 Intellivox DDC | Installation Manual | Appendix Fig 24 LBC 3253/10 Intellivox-2c dimensions, all measures in mm Bosch Security Systems | July 2003...
Page 26
All manuals and user guides at all-guides.com EN | 27 Intellivox DDC | Installation Manual | Appendix Fig 25 LBC 3254/00 Intellivox-4c dimensions, all measures in mm. Bosch Security Systems | July 2003...
Page 27
All manuals and user guides at all-guides.com EN | 28 Intellivox DDC | Installation Manual | Appendix Fig 26 LBC 3254/10 Intellivox-4c dimensions, all measures in mm. Bosch Security Systems | July 2003...
Page 28
All manuals and user guides at all-guides.com EN | 29 Intellivox DDC | Installation Manual | Appendix Fig 27 LBC 3256/00 Intellivox-6c dimensions, all measures in mm Bosch Security Systems | July 2003...
Page 29
All manuals and user guides at all-guides.com EN | 30 Intellivox DDC | Installation Manual | Appendix Fig 28 LBC 3256/10 Intellivox-6c dimensions, all measures in mm Bosch Security Systems | July 2003...