1070 072 196-101 (00.06) GB
Protocol-specific settings for channel 0 are to be located at DIP switch S3
and S6. At DIP switch S6, only the switches 1 and 2 are assigned to channel
0.
The DIP switches S4, S5, and S6 with switch 3 and 8 are reserved for future
extensions, and must always be switched to OFF.
In general, 8 information bits and 1 stop bit are transferred.
S3
1
2
3
4
off
on
off
on
off
off
on
off
off
on
on
on
.
For further information regarding BUEP03E, BUEP19E, and BUEP64,
please refer to the manual: R500 Computer Interface Module; order
no. 1070 072 131.
5
6
7
8
Function
off
Control signals are not
scanned
on
Control signals are scanned
off
off
off
38400 baud
on
off
off
57600 baud
off
on
off
600 baud / 10400 baud for
BUEP03E with switch S6-2 on
on
on
off
1200 baud
off
off
on
2400 baud
on
off
on
4800 baud
off
on
on
9600 baud
on
on
on
19200 baud
No parity
Parity active
Odd parity
Even parity
No protocol (tracer/monitor)
BUEP19E
BUEP03E
BUEP64
Hardware