Summary of Contents for Siemens VersiCharge AC Wallbox IEC

  • Page 2 VersiCharge AC Wallbox IEC Introduction Safety information Description Mounting / Installing / Connecting VersiCharge AC Wallbox IEC Commissioning Operation Operating Instructions Faults Maintenance and service Service & Support Disposal Technical specifications Appendix List of abbreviations 12/2021 A5E50366109-AA...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Connecting the supply cable ....................29 Limiting the charging current ..................... 31 Connecting the communication cable ................33 Switching contact output ....................35 4.10 Closing the Wallbox ......................37 4.11 Switching on and testing ....................38 VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 5 Storage and transport ......................60 Cleaning and maintenance ....................60 Maintenance ........................61 Software update ........................ 62 Service & Support ..........................63 Siemens Industry Support ....................63 Disposal ............................... 64 10.1 Recycling and disposal ....................... 64 Technical specifications ........................65 11.1...
  • Page 6: Introduction

    Introduction Purpose of this documentation These operating instructions contain the information required for installing, commissioning, and operating the VersiCharge AC Wallbox IEC. The operating instructions contain information on the proper use of the Wallbox. WARNING Personal injury and damage to property when the information is not observed...
  • Page 7: Open-Source Software

    Siemens accepts no liability for the use of the open-source software over and above the intended program sequence, or for any faults caused by modifications to the software.
  • Page 8: Safety Information

    • Building regulations for parking spaces for electric cars including Wallbox. • Guideline of the electricity supplier • Equipment and foundation statics The instructions in the documentation do not replace statutory safety instructions. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 9 Unauthorized opening of the device Risk of electric shock Only qualified personnel may open the device. Unauthorized persons risk causing considerable property damage, serious injuries, or death. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 10 When tripping over a charging cable, it can be unintentionally ripped out from the socket outlet and cause damage to the vehicle or Wallbox. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 11: Safety During Setup, Installation And Maintenance

    Leave sufficient clearance to surrounding obstacles to avoid collisions and crushing when setting up the Wallbox. There must be no objects on the ground in the working area to rule out the risk of tripping. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 12: Safety During Electrical Installation

    Defective connectors or cables may cause fire. Decommission the system if there are defects. Have the defective parts repaired by qualified personnel. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 13: The Five Safety Rules For Electrical Work

    After finishing the work, remove the protective measures and switch the system on again: 1. Remove short-circuit 2. Remove grounding 3. Remove covers or barriers 4. Remove fuse to prevent restart 5. Switch the system back on VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 14: Safety During Operation

    Do not bend or squeeze the charging cable; do not run it over sharp edges, and use it only within the permissible temperature range. Inspect sockets and the charging cable for damage on a regular basis. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 15: Security Information

    In order to protect plants, systems, machines, and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute one element of such a concept. Operators of the Wallbox are responsible for preventing unauthorized access to their plants, systems, machines and networks.
  • Page 16: Safety-Relevant Symbols

    Note that a device may be exposed to electrical voltages which can be dangerous. ANSI Z535.2 Do not dispose of the old device with household waste. Follow local, national, and international regulations for disposal. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 17: Description

    • Connectable charging socket Type 2 or permanently installed charging cable with Type 2 plug according to IEC 62196 • Communication via Open Charge Point Protocol (OCPP) In conjunction with a Siemens backend system (e.g. Siemens Device Management), the Wallbox offers additional functions: • Connection and control via network, smartphones, and digital terminals •...
  • Page 18: Structure Of The Wallbox

    ⑤ Mount point of wall bracket ⑥ Entry of supply cable ⑦ Entry of communication cable ⑧ SIM card slot ⑨ MID counter ⑩ Connecting terminals ⑪ LAN interface Figure 3-1 Structure VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 19: User Interface Structure

    Multifunction display for charging status / RFID / time delay / error conditions ⑥ Touch button ⑦ RFID reader ⑧ Status LED Error ⑨ Status LED Charging active ⑩ Status LED Power ⑪ Status LED Vehicle connected Figure 3-2 Structure of the Wallbox VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 20: Scope Of Delivery

    6x fastening screw DIN 7996 5x40 ④ 6x dowel 8x40 ⑤ 1x securing screw ISO 14583 M3x8 ⑥ 1x ferrite core ⑦ 1x reducer cable entry ⑧ 2x RFID card Admin ⑨ 5x RFID card User VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 21: Meter

    Information on the nameplate will help service and support with troubleshooting and procuring matching spare parts. For this reason, do not remove the rating plate. Make sure that the information is legible. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 22 G= RFID, without credit card function ⑨ A= Default color Silver Metallic Pantone 10077, Default cover ⑩ 0= Child type 1= Parent type without SIM card 2= Parent unit including SIM card preconfigured VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 23: Mounting / Installing / Connecting

    Wallbox. The following points describe the step-by-step mounting of the Wallbox. Additional steps may be necessary at your location of use. These assembly instructions therefore do not claim to be exhaustive. See also Preparations for mounting (Page 23) VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 24: Preparations For Mounting

    • Spirit level • If applicable, crimping tool and installation tool for RJ45 plug Tools for stone wall or concrete wall: • Impact drill • Masonry drill ∅ 8 mm • Hammer VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 25: Assembly Procedure

    Wallbox. • Ensure that there is sufficient clearance to the surrounding obstacles when setting the load down. • Keep the working area free of objects to avoid the risk of tripping. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 26 Before starting the installation work, check that the supply cable has been disconnected from the mains and secured against restart. If damage or tampering is visible (e.g. on the enclosure, socket), do not operate the Wallbox. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 27 2. Align the wall bracket to the mounting surface using a spirit level. Use the wall bracket to mark the mounting holes. Figure 4-2 Drill picture 3. Put the wall bracket to one side and drill the holes in the wall. 4. Insert the dowels in the drilled holes. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 28: Requirements For The Electrical Connection

    A Type A circuit breaker is generally sufficient due to the integrated DC fault current monitoring. Also note the regulations in place for upstream protection from transient overvoltages (e.g. through lightning), for example, by using SPDs (Surge Protection Device) according to IEC 60364-7-722. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 29: Wiring Position

    Hook the Wallbox into the upper and lower notch of the wall bracket. Remove protective cover: Remove the protective cover of the Wallbox by pressing the two clips upwards to obtain access to the electronics. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 30: Connecting The Supply Cable

    For TN-C networks, a cable bridge N-PE must be used if necessary. Procedure DANGER Risk of electric shock When connecting the Wallbox, pay attention to the five safety rules (see also The five safety rules for electrical work (Page 12)). VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 31 2. Tighten the nuts of the cable gland by hand to ensure a tight seal and strain relief. Use the supplied reducer for cables with 9 to 15 mm outer diameter. Check that the seal is sitting correctly. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 32: Limiting The Charging Current

    Only a qualified electrician can limit the maximum charging current to the infeed power using the rotary switch. The design and protection of the supplying current circuit must be adapted to the set charging current. Observe the local regulations and connection conditions. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 33 4. Close and secure the cover of the Wallbox. Check that the seal is sitting correctly. Note In positions 5 to 9, the current is increased to no higher than the maximum value for which the hardware is designed. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 34: Connecting The Communication Cable

    3. Guide the cables through the sealing insert at the bottom of the device into the Wallbox. 4. Mount the required plug-in connectors. Follow the specifications of the connector manufacturer. 5. Insert the necessary connectors into the corresponding socket on the board. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 35 ON. On all devices in between, set this switch to OFF. Additional information You can find additional information on the topic of communication here (Page 44). VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 36: Switching Contact Output

    An example of a protective circuit is shown in this section. Requirements: • Firmware version 2.113.0.99 or higher is required Technical specification for the switching contact output (input/output): • 2x 0.5 mm² cross section • Vn: 24V (Vmax: 30V) • Imax: 3A VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 37 Technical documentation of the compo- nent manufacturer must be observed. Note: ** Multiple current releases Several shunt releases can be supplied via one AC/DC power supply unit, see specification of the compo- nents used. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 38: Closing The Wallbox

    Wallbox into the wall bracket. Lift the Wallbox from the wiring position and close the Wallbox by placing the Wallbox onto the wall bracket. Secure the Wallbox against unauthorized opening with the supplied M3x8 screw. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 39: Switching On And Testing

    3. Complete the commissioning report in accordance with the regional regulations, e.g. DGUV regulation 3. Note The Wallboxes are designed for continuous operation. Daily reboots (power cycle) may affect the service life of the components. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 40: Commissioning

    RFID (local share list) is possible. Commissioning with PC or mobile device For the integrated functions of the Wallbox, you need an Internet connection to connect to Siemens Device Management. The connection is set up during the commissioning described here. Preparing commissioning Commission the Wallbox either with your mobile device using the VersiCharge app or with a PC tool.
  • Page 41 – Mobile Internet (SIM card only in the Parent device) – Wi-Fi – Ethernet 5. Connect the Wallbox to Siemens Device Management. This takes place automatically. 6. Assign a descriptive name for the Wallbox. 7. Check the settings. You can find detailed commissioning instructions here (https://siemens.com/versicharge).
  • Page 42: Notes On Setting Up The Communication Connection

    If you want to change network settings such as SSID and password after the Wallbox has been successfully connected to Siemens Device Management, proceed as follows: 1. Delete the link of the Wallbox with Siemens Device Management via the VersiCharge app or via VersiCharge Siemens Cloud (https://versicharge.emobility.siemens.cloud/).
  • Page 43: Wi-Fi Connection

    8EM131x-xxxxx-3xx2 are delivered equipped with a factory-fitted SIM card for the connection to the Siemens Device Management system (and also to the Siemens OCPP backend if appropriate). Note that the mobile wireless data connection can incur costs.
  • Page 44 • If appropriate, password and user name Note Devices that are delivered with a factory-fitted SIM card (8EM131x-xxxxx-3xx2) require the following parameters to establish a connection to the Siemens Device Management System: • Modem dial string: *99# • APN: cu.siemens.global •...
  • Page 45: Overview Of Modbus, Rs485 And Ethernet

    • Provide data in real time via the Modbus protocol Parent Modbus devices have the following tasks: • Read-only access to this data • Write data to the registers of your meter • Change the device configuration • Initiate control actions VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 46: Setting Communication

    • OCPP-based server • On the device using Admin RFID cards The management of RFID cards via Admin cards in the local, preconfigured list is described under Releasing or locking RFID cards. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 47 1 K, 2 K, 4 K AES, Crypto1 ISO14443A Part 1–4 MIFARE DESFire 2 K, 4 K, 8 K AES, 3DES ISO14443A Part 1–4 MIFARE Ultralight 40, 48, 128, 144 None, 3DES ISO14443A Part 1–3 VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 48 If necessary, repeat this process as often as desired. 4. Hold an Admin card in front of the RFID reader to end management of RFID cards. An acoustic signal is emitted. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 49: Operation

    Lights up white Vehicle connected Lights up white Charging in progress Lights up white After switch-on, the charger will go Connect PC or mobile device for commissioning to Access Point mode Flashes white VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 50 Commissioning with PC or mobile device (Page 39). Lights up orange Charger is connected to router. Strong Wi-Fi. Lights up green Attempting to connect to Siemens Device Management Flashes blue Ready for operation (with success- ful connection and registration in Siemens Device Management)
  • Page 51 6.1 Status displays Display Description Action Access blocked Unlock via RFID/OCPP/Modbus Lights up blue 2 h delay Wait until charging process starts. Flashes white 4 h delay Wait until charging process starts. Flashes white VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 52 Press the Touch button for 5 sec- Power presetting is set to the maximum for the charging onds for maximum charging power process. Note: Function is inactive with an existing OCPP connection. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 53: Charging

    Status LED. You have the option of preselecting a time delay and viewing the status via the VersiCharge app. After the charging process ends, the device switches to "Ready" status (LED display (Page 18)). VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 54 • The vehicle is not drawing power. – The Wallbox is pausing, for example, because of load management – The vehicle pauses the charging • The charging of the vehicle battery is completed. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 55 4. Remove the plug from the socket of your electric vehicle. 5. Remove the plug from the Wallbox. 6. Stow away the provided charging cable. To do this, follow the instructions in the manual for your vehicle. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 56: Faults

    Repeating commissioning / logoff from Siemens Device Management If this is necessary, follow these steps: 1. With the device switched on, delete the link of the Wallbox to the Siemens Device Management – in the VersiCharge app under Account > My Charger > Deregister Charger or –...
  • Page 57 Turn the supply voltage off and on again. curred Flashes red Fault has occurred Error code: 001. Notify Technical Support. Lights up red Fault has occurred Error code: 002. Notify Technical Support Lights up red VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 58 Fault has occurred Error code: 003. Notify Technical Support Flashes red Fault has occurred Error code: 004. Notify Technical Support Flashes red Fault has occurred Error code: 005. Notify Technical Support Flashes red VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 59 Fault has occurred Error code: 006. Notify Technical Support Flashes red Fault has occurred Error code: 007. Notify Technical Support Flashes red Fault has occurred Error code: 008. Notify Technical Support Flashes red VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 60 For safety reasons, such settings overwrite all commands in the Wallbox and end the charging process. Adapt the settings in your electric vehicle. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 61: Maintenance And Service

    Do not use steam jets or water jets for cleaning, as they may cause moisture to ingress the Wallbox. Moisture inside the Wallbox poses a risk of electric shock. The manufacturer is not liable for damage resulting from improper cleaning methods. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 62: Maintenance

    Wallbox must be checked regularly to prevent overheating of cables and resulting damage. Note Only qualified personnel trained for these activities may perform this work. The appendix contains the following lists: • Installation and maintenance schedule (Page 69) VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 63: Software Update

    Siemens makes software updates available as part of continuous function extensions and improvements. The software updates are installed automatically. Make sure that the Internet connection is available. Also read the information about this at the Siemens Care Remote Service on the Internet (https://siemens.com/emobility-care) VersiCharge AC Wallbox IEC...
  • Page 64: Service & Support

    All the information and extensive know-how on your product, technical specifications, FAQs, certificates, downloads, and manuals. • mySupport Your personal working area in Siemens Industry Online Support for notifications, support queries, and configurable documents. This information is provided by Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/)on the internet.
  • Page 65: Disposal

    Dispose of the device in accordance with the applicable regulations in your country. "Waste electrical equipment must not be disposed of as unsorted municipal waste, e.g. household waste. The current local national/international regulations must be observed for disposal." VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 66: Technical Specifications

    Technical specifications 11.1 Technical specifications Performance features and options VersiCharge AC Wallbox IEC Designation Charging mode according to IEC 61851-1 Mode 3 Connection to vehicle according to IEC 62196-2 8EM1310-..H..-…. : Socket Type 2 8EM1310-..J..-…. : Permanently connected charging cable...
  • Page 67 Technical specifications 11.1 Technical specifications VersiCharge AC Wallbox IEC Designation Interfaces Ethernet, WiFi (Dual-Band), RS-485 Parent types 8EM1310-….-3... additionally GSM, 4G, LTE Communication protocols OCPP 1.6J Modbus RTU Modbus TCP Parent/Child Up to 9 child types per parent SIM card (recommended data volume) 250 MB / month RFID acc.
  • Page 68: Appendix

    SIM card 22 kW / AC 400 V Child 8EM1310-3EJ04-0GA0 22 kW / AC 400 V Parent 8EM1310-3EJ04-3GA2 incl. SIM card 22 kW / AC 400 V Parent 8EM1310-3EJ04-3GA1 without SIM card VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 69: Accessories

    A.2 Accessories Accessories Protection of persons and wiring Siemens offers residual current circuit breakers and miniature circuit breakers as accessories. The trained electrician makes the selection according to the local conditions and regulations at the place of use. The following table shows possible combinations of circuit breakers in connection with the Wallbox variant, including rated current setting.
  • Page 70: Installation And Maintenance Schedule

    • Accumulation of snow around the Wallbox Contact the supplier if you notice any anomalies. Avoid accumulation of snow around the Wallbox. Clear the area accordingly. In heavy snowfall, clear the area daily. VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 71 • Housing Commissioning with the mobile app / PC tool Check • Fault message • Backend connection (e.g. Siemens Device Management) • SIM card Cleaning Check charging sockets or charging cables • Charging cable and plug for damage Measurements acc. to DIN VDE, e.g.: •...
  • Page 72: Dimensions Of The Wallbox

    Note that the dimensions of the Wallbox with permanently installed charging cable and Type 2 plug according to IEC 62196 differ and you will need additional space. Figure A-2 Distances at the wall and between adjacent Wallboxes VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 73: Quality Documentation

    The declaration of conformity is kept available for the competent authorities at: Siemens AG Smart Infrastructure Distribution Systems Mozartstr. 31c 91052 Erlangen, Germany These files are also available for download on the Siemens Industry Online Support (https://support.industry.siemens.com/cs/de/en/view/109794281) pages, under "Declaration of Conformity". VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 74: List Of Abbreviations

    Radio Frequency Identification Radio frequency technology for identification Rich Site Summary Data format for summarizing article series and message series Schlüsselweite (for wrenches) Width across flats WiFi Wireless Fidelity Specific type of WLAN VersiCharge AC Wallbox IEC Operating Instructions, 12/2021, A5E50366109-AA...
  • Page 75: Index

    Index Amperage:, 32 Safety rules for electrical work, 12 App, 39 Service plan, 69 Siemens Care Remote Service, 62 Siemens Device Management, 39 Status displays, 48 Support, 63 CE marking, 72 Charging, 52 checklist, 69 VersiCharge Configurator, 40 DIP switch settings, 34...