Test Development Overview
54

Procedure for Viewing Test Results

If you are running a bit error measurement, the Bit Error Rate
Measurement Display window shows you actual and accumulated results.
The display is updated every second. For details see "How to View BER
Test Results" on page 184.
If you have been running one of the other tests:
1 Open the Error State Display.
The Error State Display shows the captured DUT output data. If you
have been running one of the compare tests, it shows also the deviations
between the captured and expected data. Various address and data
formats support the investigation.
For details see "How to View Captured Test Results" on page 189.
2 Open the Waveform Viewer.
The Waveform Viewer enables you to display generated and captured
data as well as compare results graphically in a variety of formats.
For details see "How to View Waveforms" on page 193.
HP 81200 Data Generator/Analyzer Platform User Guide, Revision 2.1