Bosch C 80 Manual page 46

Data logger and sensor interface
Table of Contents

Advertisement

10 | CAN Configuration
46 / 144
d) Enter data position, length and format.
e) The bargraph shows assignment of the bytes.
– Red colored fields show the assignment of the data bytes.
– Orange colored fields show the assignment of the multiplexer bytes.
Representation: Bit
Some CAN devices need to be addressed by a bit represented CAN channel. The address
can be assigned in this window and is illustrated by a matrix table.
a)
b)
c)
d)
e)
a) Enter CAN message ID. If extended IDs (29 bit) are used, check the box.
b) If replacement values are used, specify time-out period and raw value.
c) If a multiplexer (row counter) is used, check the box.
d) Enter data position, length and format.
e) The bargraph shows assignment of the bytes.
– Red colored fields show the assignment of the data bytes.
– Orange colored fields show the assignment of the multiplexer bytes.
Conversion to physical value
a)
b)
c)
d)
a) Enter factor (gain) for conversion to physical value.
b) Enter offset for conversion to physical value.
c) Select type of physical value.
d) Select unit of physical value.
e) Enter minimum physical limit of the channel. (for manual setup)
f) Enter maximum physical limit of the channel. (for manual setup)
Manual_C_80
e)
f)
g)
Bosch Motorsport