50/83
Bosch Rexroth AG
PC Box
CAUTION
⇒ Use an isolating transformer to generate the AC 230/115 V,, see
"Wiring of the DC 24 V power connection to the VSB 40.1" on page
The AC 230/115 V connection occurs via a 3-pin inlet connector for AC con‐
nectors on the connector panel. The maximum line cross-section for the con‐
nected lines is 1.5 mm
.
2
PE
PE
Fig.7-22:
Pin assignment of the AC 230/115 V connection, X20
Parameter
Rated voltage
Current consumption for U
N
Current consumption for U
N
Inrush current for AC 264 V
Overload protection
Short-circuit protection
Fig.7-23:
Technical data AC 115/230 V connection
DOK-SUPPL*-VSB*40.1***-PR03-EN-P
Rexroth IndraControl VSB 40.1 Control Cabinet PC
The supply voltage must comply with overvolt‐
age category II! Otherwise the integrated pow‐
er supply unit might be destroyed.
X20
PE
Value
AC 85 V... AC 264 V auto range
= AC 230 V
2.5 A
= AC 115 V
5 A
100 A
As of 135 %, deactivation
At all outputs, deactivation
fig. 7-21
49.
Belegung
Assignment
N1
U2