thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
Please register your product with sealey by completing the registration form on-line at www.sealey.co.uk
navigate to register Product. By registering your product you can take advantage of sealey product and technical updates via email.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Wear eye
refer to
Protection
instructions
1. safety
WARNING! Ensure that Health and Safety, local authority and general workshop practice regulations are strictly adhered to.
Do Not use the unit if it, or any attachment, is damaged.
8
maintain tester in good and clean condition for best and safest performance.
9
if required, ensure that the vehicle to be worked on is adequately supported with axle stands or ramps and is chocked.
9
Put transmission in PArK (for automatic transmission) or neutrAl (for manual transmission) and make sure the parking brake is
9
engaged.
Wear approved eye protection. A full range of personal safety equipment is available from your sealey dealer.
9
Wear suitable clothing to avoid snagging. do not wear jewellery and tie back long hair.
9
WarNiNg! use extreme caution when working around the ignition coil, distributor cap, ignition wires and spark plugs. these
components create hazardous voltages when the engine is running.
Do Not connect or disconnect any test equipment with ignition on or engine running.
8
Keep a fire extinguisher nearby, which is suitable for gasoline/chemical/electrical fires.
9
Account for all tools and parts being used and do not leave any in the engine bay.
9
Keep reset tool dry, clean and free from oil, water and grease. use a mild detergent on a clean cloth to clean the outside of the tool.
9
operate the vehicle in a well-ventilated work area; exhaust gases are poisonous.
9
imPortAnt: Always refer to the vehicle manufacturer's service instructions to establish the current procedure and data. these
9
instructions are provided as a guide only.
WarNiNg! the warnings and instructions discussed in this manual cannot cover all possible conditions and situations that may occur.
it must be understood that common sense and caution are factors which cannot be built into this product, but must be applied by the
operator.
When not in use, store tester away in its box, in a cool, dry, childproof location.
9
2. iNtroDuctioN
designed for resetting electronic Parking Brake (ePB) and extinguishing the service interval lights,
including the service interval messages, that are displayed in the driver information module after
carrying out routine maintenance on Volvo vehicles. simple push button application. Powered by
connection to the vehicle.
3. operatioN
3.1.
the Vs8625 tool:
is compatible with the latest CAN vehicles.
enables service and repair functions to be carried out on EPB systems.
3.2.
the new Vs8625 Volvo slr and ePB tool has been designed to allow users to
extinguish the service light following the servicing of a vehicle. it also allows for the
servicing and replacement of brake pads and components used in the new
electronic Parking Brake systems which have been introduced to the Volvo range.
3.3.
slr functions
reset service light –this tool will extinguish the service light on the dashboard after a
service has been carried out.
reset service– reset the service interval messages displayed on the driver information
module.
ePB open –this tool allows the callipers to be retracted allowing the brake pads to be
removed for service. This also provides assistance in fitting new Park Brake
motors, brake calipers and discs, as well as replacing wheel hubs as the callipers
are retracted, releasing braking components.
ePB close – After servicing, the callipers can be advanced to their original position without the
current calibration being effected.
© Jack sealey limited
instructions for
service light & epb reset tool
model no:
TECHNICAL HELP LINE No. 01284 757505
Wear Protective
electrical
clothing
shock
Hazard
Original Language Version
vs8625
VS8625 | Issue 2 29/06/16

Advertisement

loading

Summary of Contents for Sealey VS8625

  • Page 1 Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. TECHNICAL HELP LINE No. 01284 757505 Please register your product with sealey by completing the registration form on-line at www.sealey.co.uk...
  • Page 2 3.8.4. Once the function has completed, the function LED will flash to indicate a successful reset. 3.2.5. If the function is unsuccessful, the Service Mode LED will flash. Original Language Version VS8625 | Issue 2 29/06/16 © Jack sealey limited...
  • Page 3 Any codes that are not able to be cleared will remain on the module. use the sealey Vst electronic Auto service and diagnostic tool to determine what these codes are and what steps need to be taken to resolve the problem.
  • Page 4 WarraNty: Guarantee is 12 months from purchase date, proof of which will be required for any claim. sole uK distributor, sealey Group. 01284 757500 www.sealey.co.uk Kempson Way, suffolk Business Park, Bury st. edmunds, suffolk. 01284 703534 sales@sealey.co.uk iP32 7AR Original Language Version VS8625 | Issue 2 29/06/16 © Jack sealey limited...