X500, X501: DRIVE-CLiQ interface
Table 9- 7
Connector
Blanking plate for DRIVE-CLiQ interfaces (50 units) Article number: 6SL3066-4CA00-0AA0
X520: 4 digital inputs
Table 9- 8
Connector
Max. connectable cross-section: 1.5 mm²
DI: digital input; M1: ground reference; M: Electronics ground
1)
Cabinet Modules liquid cooled
Equipment Manual, 04/2020, A5E37067587A
DRIVE-CLiQ interface X500 and X501
Pin
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
B
M (0 V)
Terminal block X520
Terminal
Designation
1
DI 0
2
DI 1
3
DI 2
4
DI 3
5
M1
6
M
Signal name
1)
Voltage: - 3 ... +30 V
Current consumption typical: 10 mA at 24 V DC
Input delay:
for "0" to "1": Typ. 50 µs max. 100 µs
for "1" to "0": Typ. 130 µs, max. 150 µs
Electrical isolation:
Reference potential is terminal M1
Signal level (including ripple)
High level: 15 ... 30 V
Low level: -3 ... +5 V
9.7 G60, Terminal Module TM31
Technical data
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground
Technical data