Emergency Stop Button; Emergency Stop Led - ABB HD5-S Original Instructions Manual

Three-position device
Table of Contents

Advertisement

Emergency stop button

The built-in emergency stop button has two force guided normally closed contacts.
The emergency stop button shall initiate an emergency stop function, thereby removing
energy to the hazardous functions in the event of emergency.
The holders developed for this three-position device allow for the emergency stop
button to be pressed when the three-position device is placed in the holder.
LEDs integrated in the housing indicate the status of the emergency stop button.
Note on safe actuation
To allow for the emergency stop button to operate safely, we recommend using the holders designed for
this three-position device. See the accessories section.
Attention!
Caution should be exercised in relation to three-position devices that are connected, as standard, using a
connector. Be aware of the following items:
The correct function of the emergency stop must be check monthly!
The emergency stop function must always be functional and should have priority over all other
functions and operations in all operating modes of the machine without affecting any system
intended to release trapped persons.
No start command (whether intentional, unintentional or unexpected) should be able to affect
working processes that were stopped by initiating the emergency stop function until the
emergency stop function has been reset manually.
If it is possible to remove emergency stop buttons (e.g. portable programming devices) or shut
down sections of a machine, it must be ensured that operational and non-operational
emergency stop buttons are not mixed.

Emergency stop LED

A row of LEDs is integrated in the housing, below the emergency stop button. The LEDs are user-defined
and can be controlled in via wiring.
Red LED row
Green LED row
2TLC010052M0201_A