Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.

3.2.22 Sescoa Super Speed (Message Type 7)

Sescoa Super
SIA Mode Description
Speed
<LF><CRC><7><sequence#><receiver#><line#>[#aaaa| IAAC]<CR>
Example
Table 78: Sescoa Super Speed (Message Type 7) Byte Description
Title
LF
CRC
Message Type
sequence#
receiver#
line#
(Line/Group #)
account#
I
AA
C
Figure 23: Message sent to printer
mm/ddshh:mmsLxxSESsACCTsaaaa +++sACCTsaaaasEEEseeeeeeeeeeeeee
For lines that are grouped, Gxx appears instead of Lxx.
Table 79: Sescoa Super Speed (Message Type 7) Printer Output
Characters
Description
SES
SESCOA Super Speed format.
Lxx
Line number.
Gxx
Grouped line numbers.
aaaa
Account code.
EEE
SESCOA Super Speed format event.
eeeeeeeeeeee
Up to 14-characters of event description.
ee
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Description
Standard line feed character.
Cyclical redundancy check number.
7
The message sequence number. The valid sequence number range is 0001
to 9999.
The receiver gateway that sent the message. Valid digits are 01 to 99 for
D6600/D6100/D6100IPv6.
The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.
The communicator's account number has four digits.
Event code.
Two- digit zone code or the first two digits user code.
Space if zone report, or the last digit user code.